    A Musculoskeletal Model Customized for Sagittal and Frontal Knee Kinematics With Improved Knee Joint Stability

    Source: Journal of Biomechanical Engineering:;2022:;volume( 144 ):;issue: 007::page 71010-1
    Author:
    Giri, Shivangi
    ,
    Tewari, Ravi Prakash
    ,
    Salhi, Asma
    ,
    Lempereur, Matthieu
    ,
    Borotikar, Bhushan
    DOI: 10.1115/1.4053666
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Current lower limb musculoskeletal (MSK) models focus on sagittal plane kinematics. However, abnormal gait is typically associated with sagittal plane motions crossing into other planes, limiting the use of current MSK models. The purpose of this study was twofold, first, to extend the capability of a full-body MSK model from the literature to include frontal knee plane kinematics during healthy gait, and second, to propose and implement a realistic muscle discretization technique. Two MSK model constructs were derived—the first construct (Knee2_SM) allowed two degrees-of-freedom (sagittal and coronal) at the knee and the second construct (Knee2_MM) implemented multiline elements for all the lower limb muscles in conjunction with two knee degrees-of-freedom. Motion analysis data of normal gait cycle from 10 healthy adults were used to compare joint kinematics, muscle moment arms, muscle forces, and muscle activations, between new constructs and the original model. Knee varus-valgus trajectories were estimated with the mean peak values ranging from 9.49 deg valgus to 1.57 deg varus. Knee2_MM predicted a significant difference (p <
     
     0.05) in moment arms and forces in those muscles responsible for medial–lateral stability of the knee. The simulated muscle activations generated by the Knee2_MM model matched more closely to the experimental electromyography (EMG) when qualitatively compared. This study enhances the capability of the sagittal plane full-body MSK model to incorporate knee varus-valgus motion while keeping the joint stability intact and improving muscle prediction.
     
    • Download: (2.837Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      A Musculoskeletal Model Customized for Sagittal and Frontal Knee Kinematics With Improved Knee Joint Stability

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4283826
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorGiri, Shivangi
    contributor authorTewari, Ravi Prakash
    contributor authorSalhi, Asma
    contributor authorLempereur, Matthieu
    contributor authorBorotikar, Bhushan
    date accessioned2022-05-08T08:21:04Z
    date available2022-05-08T08:21:04Z
    date copyright2/21/2022 12:00:00 AM
    date issued2022
    identifier issn0148-0731
    identifier otherbio_144_07_071010.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4283826
    description abstractCurrent lower limb musculoskeletal (MSK) models focus on sagittal plane kinematics. However, abnormal gait is typically associated with sagittal plane motions crossing into other planes, limiting the use of current MSK models. The purpose of this study was twofold, first, to extend the capability of a full-body MSK model from the literature to include frontal knee plane kinematics during healthy gait, and second, to propose and implement a realistic muscle discretization technique. Two MSK model constructs were derived—the first construct (Knee2_SM) allowed two degrees-of-freedom (sagittal and coronal) at the knee and the second construct (Knee2_MM) implemented multiline elements for all the lower limb muscles in conjunction with two knee degrees-of-freedom. Motion analysis data of normal gait cycle from 10 healthy adults were used to compare joint kinematics, muscle moment arms, muscle forces, and muscle activations, between new constructs and the original model. Knee varus-valgus trajectories were estimated with the mean peak values ranging from 9.49 deg valgus to 1.57 deg varus. Knee2_MM predicted a significant difference (p <
    description abstract 0.05) in moment arms and forces in those muscles responsible for medial–lateral stability of the knee. The simulated muscle activations generated by the Knee2_MM model matched more closely to the experimental electromyography (EMG) when qualitatively compared. This study enhances the capability of the sagittal plane full-body MSK model to incorporate knee varus-valgus motion while keeping the joint stability intact and improving muscle prediction.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleA Musculoskeletal Model Customized for Sagittal and Frontal Knee Kinematics With Improved Knee Joint Stability
    typeJournal Paper
    journal volume144
    journal issue7
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.4053666
    journal fristpage71010-1
    journal lastpage71010-12
    page12
    treeJournal of Biomechanical Engineering:;2022:;volume( 144 ):;issue: 007
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian