Lateral Pile Resistance, Wall Displacement, and Induced Reinforcement Force for Laterally Loaded Single Piles Near Mechanically Stabilized Earth WallsSource: Journal of Geotechnical and Geoenvironmental Engineering:;2021:;Volume ( 148 ):;issue: 003::page 04021197Author:Kyle M. Rollins
,
Andrew Luna
,
Ryan Budd
,
Jason Besendorfer
,
Cody Hatch
,
Jarell Han
,
Robert Gladstone
DOI: 10.1061/(ASCE)GT.1943-5606.0002739Publisher: ASCE
Abstract: A full-scale mechanically stabilized earth (MSE) wall was constructed with inextensible reinforcements, and 23 lateral load tests were conducted on single piles spaced at distances of about 2 to 5 pile diameters (D) from the back face of the wall to the center of the pile. Tests were performed on pipe, square, and H-piles. Lateral resistance decreased significantly when piles were located closer than about 4D from the wall. P-multipliers were developed to account for the reduction in lateral soil resistance for piles near the wall and were approximately 1 for piles located further than about 4D from the wall but decreased linearly for smaller distances. They provided a reasonable means for estimating reduced lateral resistance and were not significantly affected by differences in reinforcement length, reinforcing type, or pile shape. Measured tensile force in the reinforcements tended to reach a peak near the pile rather than at the wall face. Equations are developed to predict maximum tensile force in the reinforcements. Tensile force increased with pile head load and decreased with increased transverse distance from the load point.
|
Show full item record
| contributor author | Kyle M. Rollins | |
| contributor author | Andrew Luna | |
| contributor author | Ryan Budd | |
| contributor author | Jason Besendorfer | |
| contributor author | Cody Hatch | |
| contributor author | Jarell Han | |
| contributor author | Robert Gladstone | |
| date accessioned | 2022-05-07T21:19:11Z | |
| date available | 2022-05-07T21:19:11Z | |
| date issued | 2021-12-28 | |
| identifier other | (ASCE)GT.1943-5606.0002739.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl1/handle/yetl/4283578 | |
| description abstract | A full-scale mechanically stabilized earth (MSE) wall was constructed with inextensible reinforcements, and 23 lateral load tests were conducted on single piles spaced at distances of about 2 to 5 pile diameters (D) from the back face of the wall to the center of the pile. Tests were performed on pipe, square, and H-piles. Lateral resistance decreased significantly when piles were located closer than about 4D from the wall. P-multipliers were developed to account for the reduction in lateral soil resistance for piles near the wall and were approximately 1 for piles located further than about 4D from the wall but decreased linearly for smaller distances. They provided a reasonable means for estimating reduced lateral resistance and were not significantly affected by differences in reinforcement length, reinforcing type, or pile shape. Measured tensile force in the reinforcements tended to reach a peak near the pile rather than at the wall face. Equations are developed to predict maximum tensile force in the reinforcements. Tensile force increased with pile head load and decreased with increased transverse distance from the load point. | |
| publisher | ASCE | |
| title | Lateral Pile Resistance, Wall Displacement, and Induced Reinforcement Force for Laterally Loaded Single Piles Near Mechanically Stabilized Earth Walls | |
| type | Journal Paper | |
| journal volume | 148 | |
| journal issue | 3 | |
| journal title | Journal of Geotechnical and Geoenvironmental Engineering | |
| identifier doi | 10.1061/(ASCE)GT.1943-5606.0002739 | |
| journal fristpage | 04021197 | |
| journal lastpage | 04021197-10 | |
| page | 10 | |
| tree | Journal of Geotechnical and Geoenvironmental Engineering:;2021:;Volume ( 148 ):;issue: 003 | |
| contenttype | Fulltext |