    Effect of a Secondary Building Envelope on Cooling Loads in Hot Climates

    Source: Journal of Architectural Engineering:;2022:;Volume ( 028 ):;issue: 002::page 04022008
    Author:
    Sahar N. Kharrufa
    ,
    Sahar Makky
    DOI: 10.1061/(ASCE)AE.1943-5568.0000535
    Publisher: ASCE
    Abstract: Cooling buildings represent a major environmental issue, especially during summers. Although thermal insulation can decrease cooling loads, the presence of thermal bridges, infiltrations, windows, and other openings pose a continuous challenge. In the Middle East and North Africa (MENA) region, for instance, most windows are made of aluminum, a thermal conductor. This paper uses two methods to evaluate the alternative solution of enveloping buildings, including windows, with a secondary layer. The first method involved small-scale models; two test rooms were built, with one (the reference room) being based on regular municipal thermal guidelines and the other (the enveloped room) including an extra, secondary surrounding layer. The second test staged a similar scenario via software simulation. Both sets of results showed a significant reduction in electricity consumption in the enveloped room, which became more notable as the weather grew hotter. At the high end of the temperature scale, the power consumption of the enveloped room was 47%–54% lower than that of the reference room. However, such a secondary building envelope would increase the width of the wall structure and present the downside of adding to construction costs. While adopting this system in Dubai may save the city an estimated 16.6% in electrical energy, based on current prices, a house would likely need between 10 and 15 years to recuperate the associated capital investment.
    • Download: (2.140Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Effect of a Secondary Building Envelope on Cooling Loads in Hot Climates

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4282582
    Collections
    • Journal of Architectural Engineering

    Show full item record

    contributor authorSahar N. Kharrufa
    contributor authorSahar Makky
    date accessioned2022-05-07T20:32:46Z
    date available2022-05-07T20:32:46Z
    date issued2022-6-1
    identifier other(ASCE)AE.1943-5568.0000535.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4282582
    description abstractCooling buildings represent a major environmental issue, especially during summers. Although thermal insulation can decrease cooling loads, the presence of thermal bridges, infiltrations, windows, and other openings pose a continuous challenge. In the Middle East and North Africa (MENA) region, for instance, most windows are made of aluminum, a thermal conductor. This paper uses two methods to evaluate the alternative solution of enveloping buildings, including windows, with a secondary layer. The first method involved small-scale models; two test rooms were built, with one (the reference room) being based on regular municipal thermal guidelines and the other (the enveloped room) including an extra, secondary surrounding layer. The second test staged a similar scenario via software simulation. Both sets of results showed a significant reduction in electricity consumption in the enveloped room, which became more notable as the weather grew hotter. At the high end of the temperature scale, the power consumption of the enveloped room was 47%–54% lower than that of the reference room. However, such a secondary building envelope would increase the width of the wall structure and present the downside of adding to construction costs. While adopting this system in Dubai may save the city an estimated 16.6% in electrical energy, based on current prices, a house would likely need between 10 and 15 years to recuperate the associated capital investment.
    publisherASCE
    titleEffect of a Secondary Building Envelope on Cooling Loads in Hot Climates
    typeJournal Paper
    journal volume28
    journal issue2
    journal titleJournal of Architectural Engineering
    identifier doi10.1061/(ASCE)AE.1943-5568.0000535
    journal fristpage04022008
    journal lastpage04022008-11
    page11
    treeJournal of Architectural Engineering:;2022:;Volume ( 028 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian