    Evaluation of Default, Soil-Specific, and Clay Content Correction Calibration Functions for Dielectric Sensors in Soils with Differing Properties

    Source: Journal of Irrigation and Drainage Engineering:;2022:;Volume ( 148 ):;issue: 006::page 04022016
    Author:
    Urša Pečan
    ,
    Damijana Kastelec
    ,
    Marina Pintar
    DOI: 10.1061/(ASCE)IR.1943-4774.0001677
    Publisher: ASCE
    Abstract: Correct soil water content measurement is important for various environmental and agricultural applications. The aim of this study was to evaluate the performance of two commercially available dielectric sensors, the SM150T (Delta-T Devices) and TRIME-Pico 32 (IMKO). We evaluated the manufacturer’s calibration functions and the two-point calibration function recommended by Delta-T Devices. The coefficients of the two-point calibration showed a statistically significant dependence on clay content. Because the soils tested contained a wide range of clay contents, a clay content correction function was developed. Soil-specific calibration functions were also developed. In general, measurement errors were the largest when the manufacturer’s calibration was used, but were smaller for the SM150T [root mean square error (RMSE) of 0.011 to 0.051  m3 m−3] compared to the TRIME-Pico 32 (RMSE of 0.030 to 0.060  m3 m−3). The errors decreased after applying the clay content correction function for TRIME-Pico 32. For both sensor types, the two-point calibration reduced the errors, and the soil-specific calibration yielded the lowest error rates.
    • Download: (814.3Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Evaluation of Default, Soil-Specific, and Clay Content Correction Calibration Functions for Dielectric Sensors in Soils with Differing Properties

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4281704
    Collections
    • Journal of Irrigation and Drainage Engineering

    Show full item record

    contributor authorUrša Pečan
    contributor authorDamijana Kastelec
    contributor authorMarina Pintar
    date accessioned2022-05-07T19:49:41Z
    date available2022-05-07T19:49:41Z
    date issued2022-03-22
    identifier other(ASCE)IR.1943-4774.0001677.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4281704
    description abstractCorrect soil water content measurement is important for various environmental and agricultural applications. The aim of this study was to evaluate the performance of two commercially available dielectric sensors, the SM150T (Delta-T Devices) and TRIME-Pico 32 (IMKO). We evaluated the manufacturer’s calibration functions and the two-point calibration function recommended by Delta-T Devices. The coefficients of the two-point calibration showed a statistically significant dependence on clay content. Because the soils tested contained a wide range of clay contents, a clay content correction function was developed. Soil-specific calibration functions were also developed. In general, measurement errors were the largest when the manufacturer’s calibration was used, but were smaller for the SM150T [root mean square error (RMSE) of 0.011 to 0.051  m3 m−3] compared to the TRIME-Pico 32 (RMSE of 0.030 to 0.060  m3 m−3). The errors decreased after applying the clay content correction function for TRIME-Pico 32. For both sensor types, the two-point calibration reduced the errors, and the soil-specific calibration yielded the lowest error rates.
    publisherASCE
    titleEvaluation of Default, Soil-Specific, and Clay Content Correction Calibration Functions for Dielectric Sensors in Soils with Differing Properties
    typeJournal Paper
    journal volume148
    journal issue6
    journal titleJournal of Irrigation and Drainage Engineering
    identifier doi10.1061/(ASCE)IR.1943-4774.0001677
    journal fristpage04022016
    journal lastpage04022016-11
    page11
    treeJournal of Irrigation and Drainage Engineering:;2022:;Volume ( 148 ):;issue: 006
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian