Tissue Engineering for Periodontal Ligament Regeneration: Biomechanical SpecificationsSource: Journal of Biomechanical Engineering:;2020:;volume( 143 ):;issue: 003::page 030801-1Author:Gauthier, R.
,
Jeannin, Christophe
,
Attik, N.
,
Trunfio-Sfarghiu, A-M
,
Gritsch, K.
,
Grosgogeat, B.
DOI: 10.1115/1.4048810Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: The periodontal biomechanical environment is very difficult to investigate. By the complex geometry and composition of the periodontal ligament (PDL), its mechanical behavior is very dependent on the type of loading (compressive versus tensile loading; static versus cyclic loading; uniaxial versus multiaxial) and the location around the root (cervical, middle, or apical). These different aspects of the PDL make it difficult to develop a functional biomaterial to treat periodontal attachment due to periodontal diseases. This review aims to describe the structural and biomechanical properties of the PDL. Particular importance is placed in the close interrelationship that exists between structure and biomechanics: the PDL structural organization is specific to its biomechanical environment, and its biomechanical properties are specific to its structural arrangement. This balance between structure and biomechanics can be explained by a mechanosensitive periodontal cellular activity. These specifications have to be considered in the further tissue engineering strategies for the development of an efficient biomaterial for periodontal tissues regeneration.
|
Collections
Show full item record
| contributor author | Gauthier, R. | |
| contributor author | Jeannin, Christophe | |
| contributor author | Attik, N. | |
| contributor author | Trunfio-Sfarghiu, A-M | |
| contributor author | Gritsch, K. | |
| contributor author | Grosgogeat, B. | |
| date accessioned | 2022-02-05T22:24:09Z | |
| date available | 2022-02-05T22:24:09Z | |
| date copyright | 12/14/2020 12:00:00 AM | |
| date issued | 2020 | |
| identifier issn | 0148-0731 | |
| identifier other | bio_143_03_030801.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl1/handle/yetl/4277470 | |
| description abstract | The periodontal biomechanical environment is very difficult to investigate. By the complex geometry and composition of the periodontal ligament (PDL), its mechanical behavior is very dependent on the type of loading (compressive versus tensile loading; static versus cyclic loading; uniaxial versus multiaxial) and the location around the root (cervical, middle, or apical). These different aspects of the PDL make it difficult to develop a functional biomaterial to treat periodontal attachment due to periodontal diseases. This review aims to describe the structural and biomechanical properties of the PDL. Particular importance is placed in the close interrelationship that exists between structure and biomechanics: the PDL structural organization is specific to its biomechanical environment, and its biomechanical properties are specific to its structural arrangement. This balance between structure and biomechanics can be explained by a mechanosensitive periodontal cellular activity. These specifications have to be considered in the further tissue engineering strategies for the development of an efficient biomaterial for periodontal tissues regeneration. | |
| publisher | The American Society of Mechanical Engineers (ASME) | |
| title | Tissue Engineering for Periodontal Ligament Regeneration: Biomechanical Specifications | |
| type | Journal Paper | |
| journal volume | 143 | |
| journal issue | 3 | |
| journal title | Journal of Biomechanical Engineering | |
| identifier doi | 10.1115/1.4048810 | |
| journal fristpage | 030801-1 | |
| journal lastpage | 030801-13 | |
| page | 13 | |
| tree | Journal of Biomechanical Engineering:;2020:;volume( 143 ):;issue: 003 | |
| contenttype | Fulltext |