    High Pressure Vertical Axis Wind Pump

    Source: Journal of Fluids Engineering:;2021:;volume( 143 ):;issue: 005::page 051204-1
    Author:
    Keisar, D.
    ,
    Eilan, B.
    ,
    Greenblatt, D.
    DOI: 10.1115/1.4049692
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: A novel positive displacement, high pressure, vertical axis wind pump (HP-VAWP) was evaluated for the application of stand-alone high-pressure reverse-osmosis desalination and drip irrigation systems. The direct interface between a vertical axis wind turbine (VAWT) and a positive displacement pump that delivers a constant liquid volume per revolution has never been studied before. Understanding the interaction between turbine and pump efficiencies, where delivery pressure is determined by back-pressure alone, is critical for efficient design. Wind tunnel experiments were conducted on a small-scale two-bladed turbine (0.4 m2 cross-sectional area) that operated on a dynamic stall principle. At these small laboratory scales, the turbine and pump peak efficiencies were relatively low (15% and 28%, respectively); nevertheless, the system produced nearly constant pressures in excess of 1.5 bar for a broad operational range. Moreover, the system exhibited a basic self-priming capability, and the turbine could easily be braked by overloading the pump. A conservative field-scale analysis of an HP-VAWP system indicated that a medium-size turbine (12.5 m2 cross-sectional area) could attain a peak efficiency of 12.9%. Realistic efficiencies greater than 20% are attainable, significantly exceeding the 4%–8% typical peak efficiency of the widely used American multibladed wind pumps. Indeed, our research indicates that an HP-VAWP system is viable and requires further development. The benefits of zero carbon emissions during operation, high relative efficiency, and easy manufacturing and maintenance render the HP-VAWP ideal for stand-alone or off-grid environments.
    • Download: (2.085Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      High Pressure Vertical Axis Wind Pump

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4277243
    Collections
    • Journal of Fluids Engineering

    Show full item record

    contributor authorKeisar, D.
    contributor authorEilan, B.
    contributor authorGreenblatt, D.
    date accessioned2022-02-05T22:16:09Z
    date available2022-02-05T22:16:09Z
    date copyright2/8/2021 12:00:00 AM
    date issued2021
    identifier issn0098-2202
    identifier otherfe_143_05_051204.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4277243
    description abstractA novel positive displacement, high pressure, vertical axis wind pump (HP-VAWP) was evaluated for the application of stand-alone high-pressure reverse-osmosis desalination and drip irrigation systems. The direct interface between a vertical axis wind turbine (VAWT) and a positive displacement pump that delivers a constant liquid volume per revolution has never been studied before. Understanding the interaction between turbine and pump efficiencies, where delivery pressure is determined by back-pressure alone, is critical for efficient design. Wind tunnel experiments were conducted on a small-scale two-bladed turbine (0.4 m2 cross-sectional area) that operated on a dynamic stall principle. At these small laboratory scales, the turbine and pump peak efficiencies were relatively low (15% and 28%, respectively); nevertheless, the system produced nearly constant pressures in excess of 1.5 bar for a broad operational range. Moreover, the system exhibited a basic self-priming capability, and the turbine could easily be braked by overloading the pump. A conservative field-scale analysis of an HP-VAWP system indicated that a medium-size turbine (12.5 m2 cross-sectional area) could attain a peak efficiency of 12.9%. Realistic efficiencies greater than 20% are attainable, significantly exceeding the 4%–8% typical peak efficiency of the widely used American multibladed wind pumps. Indeed, our research indicates that an HP-VAWP system is viable and requires further development. The benefits of zero carbon emissions during operation, high relative efficiency, and easy manufacturing and maintenance render the HP-VAWP ideal for stand-alone or off-grid environments.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleHigh Pressure Vertical Axis Wind Pump
    typeJournal Paper
    journal volume143
    journal issue5
    journal titleJournal of Fluids Engineering
    identifier doi10.1115/1.4049692
    journal fristpage051204-1
    journal lastpage051204-9
    page9
    treeJournal of Fluids Engineering:;2021:;volume( 143 ):;issue: 005
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian