    Homogeneous and Automated Cooling of a Mold Segment by Multiple Water Jet Impingement and a Cross Air Flow

    Source: Journal of Thermal Science and Engineering Applications:;2021:;volume( 013 ):;issue: 006::page 061020-1
    Author:
    Agyeman, Emmanuel K. K.
    ,
    Mousseau, Pierre
    ,
    Sarda, Alain
    ,
    Edelin, Denis
    ,
    Lecointe, Damien
    DOI: 10.1115/1.4050569
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Multiple water jets and a cross air flow are used to cool a mold segment in a homogeneous and automated manner. The test segment was cooled from an initial temperature of 573 K. An average temperature difference of less than 3 K and a maximum temperature difference of less than 6 K were obtained along the length of the surface of the test segment during the entire duration of the cooling process as opposed to the traditional channel cooling approach where the mean and maximum temperature differences increase over time. The top surface of the test segment represents the mold/part interface which is of interest in this study. Using model predictive control (MPC) and a data-driven predictive model, the cooling speed of the test segment’s top surface was able to be maintained within ±5 K of the cooling ramp imposed. The results were compared to the results obtained when using a simpler On/Off algorithm for automated cooling. Compared to the simpler On/Off algorithm, there was an improvement in the accuracy of the cooling ramp with respect to its reference value of over 30% for most cooling ramps tested (5–25 K/min). A parametric study on the influence of the flowrates of the fluids on the cooling speed of the test segment’s surface was also conducted.
    • Download: (1.651Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Homogeneous and Automated Cooling of a Mold Segment by Multiple Water Jet Impingement and a Cross Air Flow

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4276934
    Collections
    • Journal of Thermal Science and Engineering Applications

    Show full item record

    contributor authorAgyeman, Emmanuel K. K.
    contributor authorMousseau, Pierre
    contributor authorSarda, Alain
    contributor authorEdelin, Denis
    contributor authorLecointe, Damien
    date accessioned2022-02-05T22:06:41Z
    date available2022-02-05T22:06:41Z
    date copyright4/9/2021 12:00:00 AM
    date issued2021
    identifier issn1948-5085
    identifier othertsea_13_6_061020.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4276934
    description abstractMultiple water jets and a cross air flow are used to cool a mold segment in a homogeneous and automated manner. The test segment was cooled from an initial temperature of 573 K. An average temperature difference of less than 3 K and a maximum temperature difference of less than 6 K were obtained along the length of the surface of the test segment during the entire duration of the cooling process as opposed to the traditional channel cooling approach where the mean and maximum temperature differences increase over time. The top surface of the test segment represents the mold/part interface which is of interest in this study. Using model predictive control (MPC) and a data-driven predictive model, the cooling speed of the test segment’s top surface was able to be maintained within ±5 K of the cooling ramp imposed. The results were compared to the results obtained when using a simpler On/Off algorithm for automated cooling. Compared to the simpler On/Off algorithm, there was an improvement in the accuracy of the cooling ramp with respect to its reference value of over 30% for most cooling ramps tested (5–25 K/min). A parametric study on the influence of the flowrates of the fluids on the cooling speed of the test segment’s surface was also conducted.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleHomogeneous and Automated Cooling of a Mold Segment by Multiple Water Jet Impingement and a Cross Air Flow
    typeJournal Paper
    journal volume13
    journal issue6
    journal titleJournal of Thermal Science and Engineering Applications
    identifier doi10.1115/1.4050569
    journal fristpage061020-1
    journal lastpage061020-11
    page11
    treeJournal of Thermal Science and Engineering Applications:;2021:;volume( 013 ):;issue: 006
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian