    Ni+ and He+ Implantation Effects on the Hardness and Microstructure of Heat-Treated X750 Superalloy

    Source: Journal of Nuclear Engineering and Radiation Science:;2020:;volume( 007 ):;issue: 001::page 011602-1
    Author:
    Tawfeeq, Maisaa N.
    ,
    Klassen, Robert J.
    DOI: 10.1115/1.4046716
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Nickel and Helium ion implantation-induced hardening and microstructural evolution of X750 in the heat-treated (HT) and solution annealed (SA) conditions were investigated using nano-indentation hardness testing and electron microscopy (scanning electron microscopy (SEM) and transmission electron microscopy (TEM)). Irradiation crystal damage up to ψ = 5 dpa was invoked with Ni+ implantation while He+ implantation up to CHe = 5000 appm was performed on samples the HT and SA conditions. The X750 alloy displayed generally increasing hardness with increasing Ni+ implantation damage but a perturbation in the trend occurred when ψ ≤ 0.5 dpa, and the hardness dropped by about 30% and 2% for the HT and the SA samples, respectively. TEM analysis indicated that this softening was associated with disordering and dissolution of the γ′ strengthening phase. The hardening behavior observed at higher implantation damage (ψ = 1 dpa) resulted in reformation of Al/Ti-rich regions within the microstructure phase. The hardness of the X750 increased continuously with increasing implanted He+ up to CHe = 1000 appm. This was associated with the formation of helium bubbles as observed by TEM. Slight drop in hardness in the HT condition at CHe = 5000 appm indicated that high levels of He+ implantation destabilize the γ′ precipitates as was confirmed with TEM observed disappearance of γ′ super-lattice reflections.
    • Download: (7.726Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Ni+ and He+ Implantation Effects on the Hardness and Microstructure of Heat-Treated X750 Superalloy

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4276476
    Collections
    • Journal of Nuclear Engineering and Radiation Science

    Show full item record

    contributor authorTawfeeq, Maisaa N.
    contributor authorKlassen, Robert J.
    date accessioned2022-02-05T21:51:42Z
    date available2022-02-05T21:51:42Z
    date copyright10/1/2020 12:00:00 AM
    date issued2020
    identifier issn2332-8983
    identifier otherners_007_01_011602.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4276476
    description abstractNickel and Helium ion implantation-induced hardening and microstructural evolution of X750 in the heat-treated (HT) and solution annealed (SA) conditions were investigated using nano-indentation hardness testing and electron microscopy (scanning electron microscopy (SEM) and transmission electron microscopy (TEM)). Irradiation crystal damage up to ψ = 5 dpa was invoked with Ni+ implantation while He+ implantation up to CHe = 5000 appm was performed on samples the HT and SA conditions. The X750 alloy displayed generally increasing hardness with increasing Ni+ implantation damage but a perturbation in the trend occurred when ψ ≤ 0.5 dpa, and the hardness dropped by about 30% and 2% for the HT and the SA samples, respectively. TEM analysis indicated that this softening was associated with disordering and dissolution of the γ′ strengthening phase. The hardening behavior observed at higher implantation damage (ψ = 1 dpa) resulted in reformation of Al/Ti-rich regions within the microstructure phase. The hardness of the X750 increased continuously with increasing implanted He+ up to CHe = 1000 appm. This was associated with the formation of helium bubbles as observed by TEM. Slight drop in hardness in the HT condition at CHe = 5000 appm indicated that high levels of He+ implantation destabilize the γ′ precipitates as was confirmed with TEM observed disappearance of γ′ super-lattice reflections.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleNi+ and He+ Implantation Effects on the Hardness and Microstructure of Heat-Treated X750 Superalloy
    typeJournal Paper
    journal volume7
    journal issue1
    journal titleJournal of Nuclear Engineering and Radiation Science
    identifier doi10.1115/1.4046716
    journal fristpage011602-1
    journal lastpage011602-9
    page9
    treeJournal of Nuclear Engineering and Radiation Science:;2020:;volume( 007 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian