    Design Synthesis and Preliminary Evaluation of a Novel Tool to Noninvasively Characterize Pressurized, Physiological Vessels

    Source: Journal of Medical Devices:;2020:;volume( 015 ):;issue: 002::page 025001-1
    Author:
    Jacobson, Natasha
    ,
    Driscoll, Mark
    DOI: 10.1115/1.4049088
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: A prolonged increase in intra-abdominal pressure (IAP) is life-threatening, yet commonly seen in intensive care units (ICUs). Despite this, existing clinically accepted IAP measurement techniques are invasive and not inter-rater reliable. As such, it is the effort of this research to develop a direct, noninvasive, handheld tool to measure internal pressures in pressurized, physiological vessels. The novel device uses a localized known pressure (namely, aspiration) to measure resulting tissue deformation, from which internal pressures can be divulged considering the extended Hencky solution. Two male participants were tested with the device to confirm feasibility of the theoretical device function for IAP measurement. Participants' Young's moduli of the abdominal wall were calculated with measured IAP values. Results were consistent with participant body mass indices and overall health. Average measured IAP was 0.42 kPa and 0.46 kPa at supine and inclined positions, respectively. Average measured abdominal wall elasticity was 14.91 kPa and 23.09 kPa at supine and inclined positions, respectively. These preliminary findings suggest the potential use of the device described herein as a measurement system for pressurized vessels, whereas the system will be tested on a larger sample size before recommending clinical use.
    • Download: (857.0Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Design Synthesis and Preliminary Evaluation of a Novel Tool to Noninvasively Characterize Pressurized, Physiological Vessels

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4276436
    Collections
    • Journal of Medical Devices

    Show full item record

    contributor authorJacobson, Natasha
    contributor authorDriscoll, Mark
    date accessioned2022-02-05T21:50:10Z
    date available2022-02-05T21:50:10Z
    date copyright12/18/2020 12:00:00 AM
    date issued2020
    identifier issn1932-6181
    identifier othermed_015_02_025001.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4276436
    description abstractA prolonged increase in intra-abdominal pressure (IAP) is life-threatening, yet commonly seen in intensive care units (ICUs). Despite this, existing clinically accepted IAP measurement techniques are invasive and not inter-rater reliable. As such, it is the effort of this research to develop a direct, noninvasive, handheld tool to measure internal pressures in pressurized, physiological vessels. The novel device uses a localized known pressure (namely, aspiration) to measure resulting tissue deformation, from which internal pressures can be divulged considering the extended Hencky solution. Two male participants were tested with the device to confirm feasibility of the theoretical device function for IAP measurement. Participants' Young's moduli of the abdominal wall were calculated with measured IAP values. Results were consistent with participant body mass indices and overall health. Average measured IAP was 0.42 kPa and 0.46 kPa at supine and inclined positions, respectively. Average measured abdominal wall elasticity was 14.91 kPa and 23.09 kPa at supine and inclined positions, respectively. These preliminary findings suggest the potential use of the device described herein as a measurement system for pressurized vessels, whereas the system will be tested on a larger sample size before recommending clinical use.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleDesign Synthesis and Preliminary Evaluation of a Novel Tool to Noninvasively Characterize Pressurized, Physiological Vessels
    typeJournal Paper
    journal volume15
    journal issue2
    journal titleJournal of Medical Devices
    identifier doi10.1115/1.4049088
    journal fristpage025001-1
    journal lastpage025001-7
    page7
    treeJournal of Medical Devices:;2020:;volume( 015 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian