    Human–Robot Interfaces of the NeuRoboScope: A Minimally Invasive Endoscopic Pituitary Tumor Surgery Robotic Assistance System

    Source: Journal of Medical Devices:;2021:;volume( 015 ):;issue: 001::page 011106-1
    Author:
    Dede, Mehmet İsmet Can
    ,
    Kiper, Gökhan
    ,
    Ayav, Tolga
    ,
    Özdemirel, Barbaros
    ,
    Tatlıcıoğlu, Enver
    ,
    Hanalioglu, Sahin
    ,
    Işıkay, İlkay
    ,
    Berker, Mustafa
    DOI: 10.1115/1.4049394
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Endoscopic endonasal surgery is a commonly practiced minimally invasive neurosurgical operation for the treatment of a wide range of skull base pathologies including pituitary tumors. A common shortcoming of this surgery is the necessity of a third hand when the endoscope has to be handled to allow active use of both hands of the main surgeon. The robot surgery assistant NeuRoboScope system has been developed to take over the endoscope from the main surgeon's hand while providing the surgeon with the necessary means of controlling the location and direction of the endoscope. One of the main novelties of the NeuRoboScope system is its human–robot interface designs which regulate and facilitate the interaction between the surgeon and the robot assistant. The human–robot interaction design of the NeuRoboScope system is investigated in two domains: direct physical interaction (DPI) and master–slave teleoperation (MST). The user study indicating the learning curve and ease of use of the MST is given and this paper is concluded via providing the reader with an outlook of possible new human–robot interfaces for the robot assisted surgery systems.
    • Download: (2.315Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Human–Robot Interfaces of the NeuRoboScope: A Minimally Invasive Endoscopic Pituitary Tumor Surgery Robotic Assistance System

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4276410
    Collections
    • Journal of Medical Devices

    Show full item record

    contributor authorDede, Mehmet İsmet Can
    contributor authorKiper, Gökhan
    contributor authorAyav, Tolga
    contributor authorÖzdemirel, Barbaros
    contributor authorTatlıcıoğlu, Enver
    contributor authorHanalioglu, Sahin
    contributor authorIşıkay, İlkay
    contributor authorBerker, Mustafa
    date accessioned2022-02-05T21:49:24Z
    date available2022-02-05T21:49:24Z
    date copyright1/18/2021 12:00:00 AM
    date issued2021
    identifier issn1932-6181
    identifier othermed_015_01_011106.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4276410
    description abstractEndoscopic endonasal surgery is a commonly practiced minimally invasive neurosurgical operation for the treatment of a wide range of skull base pathologies including pituitary tumors. A common shortcoming of this surgery is the necessity of a third hand when the endoscope has to be handled to allow active use of both hands of the main surgeon. The robot surgery assistant NeuRoboScope system has been developed to take over the endoscope from the main surgeon's hand while providing the surgeon with the necessary means of controlling the location and direction of the endoscope. One of the main novelties of the NeuRoboScope system is its human–robot interface designs which regulate and facilitate the interaction between the surgeon and the robot assistant. The human–robot interaction design of the NeuRoboScope system is investigated in two domains: direct physical interaction (DPI) and master–slave teleoperation (MST). The user study indicating the learning curve and ease of use of the MST is given and this paper is concluded via providing the reader with an outlook of possible new human–robot interfaces for the robot assisted surgery systems.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleHuman–Robot Interfaces of the NeuRoboScope: A Minimally Invasive Endoscopic Pituitary Tumor Surgery Robotic Assistance System
    typeJournal Paper
    journal volume15
    journal issue1
    journal titleJournal of Medical Devices
    identifier doi10.1115/1.4049394
    journal fristpage011106-1
    journal lastpage011106-10
    page10
    treeJournal of Medical Devices:;2021:;volume( 015 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian