    The Impact of an Open-Book Pelvic Ring Injury on Bone Strain: Validation of a Finite Element Model and Analysis Within the Gait Cycle

    Source: Journal of Biomechanical Engineering:;2021:;volume( 143 ):;issue: 007::page 071005-1
    Author:
    Salo, Zoryana
    ,
    Kreder, Hans
    ,
    Whyne, Cari Marisa
    DOI: 10.1115/1.4050459
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: The threshold for surgical stabilization for an open-book pelvic fracture is not well defined. The purpose of this research was to validate the biomechanical behavior of a specimen-specific pelvic finite element (FE) model with an open-book fracture with the biomechanical behavior of a cadaveric pelvis in double leg stance configuration under physiologic loading, and to utilize the validated model to compare open book versus intact strain patterns during gait. A cadaveric pelvis was experimentally tested under compressive loading in double leg stance, intact, and with a simulated open-book fracture. An intact FE model of this specimen was reanalyzed with an equivalent simulated open-book fracture. Comparison of the FE generated and experimentally measured strains yielded an R2 value of 0.92 for the open-book fracture configuration. Strain patterns in the intact and fractured models were compared throughout the gait cycle. In double leg stance and heel-strike/heel-off models, tensile strains decreased, especially in the pubic ramus contralateral to the injury, and compressive strains increased in the sacroiliac region of the injured side. In the midstance/midswing gait configuration, higher tensile and compressive FE strains were observed on the midstance side of the fractured versus intact model and decreased along the superior and inferior pubic rami and ischium, with midswing side strains reduced almost to zero in the fractured model. Identified in silico patterns align with clinical understanding of open-book fracture pathology suggesting future potential of FE models to quantify instability and optimize fixation strategies.
    • Download: (6.489Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      The Impact of an Open-Book Pelvic Ring Injury on Bone Strain: Validation of a Finite Element Model and Analysis Within the Gait Cycle

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4276256
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorSalo, Zoryana
    contributor authorKreder, Hans
    contributor authorWhyne, Cari Marisa
    date accessioned2022-02-05T21:44:44Z
    date available2022-02-05T21:44:44Z
    date copyright4/2/2021 12:00:00 AM
    date issued2021
    identifier issn0148-0731
    identifier otherbio_143_07_071005.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4276256
    description abstractThe threshold for surgical stabilization for an open-book pelvic fracture is not well defined. The purpose of this research was to validate the biomechanical behavior of a specimen-specific pelvic finite element (FE) model with an open-book fracture with the biomechanical behavior of a cadaveric pelvis in double leg stance configuration under physiologic loading, and to utilize the validated model to compare open book versus intact strain patterns during gait. A cadaveric pelvis was experimentally tested under compressive loading in double leg stance, intact, and with a simulated open-book fracture. An intact FE model of this specimen was reanalyzed with an equivalent simulated open-book fracture. Comparison of the FE generated and experimentally measured strains yielded an R2 value of 0.92 for the open-book fracture configuration. Strain patterns in the intact and fractured models were compared throughout the gait cycle. In double leg stance and heel-strike/heel-off models, tensile strains decreased, especially in the pubic ramus contralateral to the injury, and compressive strains increased in the sacroiliac region of the injured side. In the midstance/midswing gait configuration, higher tensile and compressive FE strains were observed on the midstance side of the fractured versus intact model and decreased along the superior and inferior pubic rami and ischium, with midswing side strains reduced almost to zero in the fractured model. Identified in silico patterns align with clinical understanding of open-book fracture pathology suggesting future potential of FE models to quantify instability and optimize fixation strategies.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleThe Impact of an Open-Book Pelvic Ring Injury on Bone Strain: Validation of a Finite Element Model and Analysis Within the Gait Cycle
    typeJournal Paper
    journal volume143
    journal issue7
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.4050459
    journal fristpage071005-1
    journal lastpage071005-7
    page7
    treeJournal of Biomechanical Engineering:;2021:;volume( 143 ):;issue: 007
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian