    In Situ Investigation of the Kinematics of Ply Interfaces During Composite Manufacturing

    Source: Journal of Manufacturing Science and Engineering:;2020:;volume( 143 ):;issue: 002::page 021006-1
    Author:
    Chava, Sandeep
    ,
    Namilae, Sirish
    DOI: 10.1115/1.4047740
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: The kinematics of composite ply interfaces critically affects both the manufacturing processes and deformation mechanisms and is often responsible for the formation of defects such as wrinkles and delamination. In the present work, processing-induced defects in a carbon fiber prepreg composite are evaluated by devising a novel in situ experimental approach. Carbon fiber prepreg laminates are cured in a specially designed autoclave with viewports with plies laid up on a mold with cylindrical tooling set up to maximize the ply-movement. Four-ply layup orientations of [90/90]s, [90/0]s, [90/45]s, and [90/−45]s and three-mold configurations with cylindrical tools of diameter 9.5 mm (3/8 in.), 12.7 mm (1/2 in.), and 15.9 mm (5/8 in.) are used for the parametric study. Strains, ply-movement, and formation of defects are observed in situ using digital image correlation (DIC) during the autoclave cure cycle, through the viewports. The processing-induced defects in the composite are further characterized by X-ray micro-computed tomography (micro-CT). We observed that the mold with the larger radius of curvature (15.9 mm cylinder) leads to higher strains in both in-plane directions and higher displacement in out of plane directions. The maximum average out-of-plane ply movement, as well as the largest wrinkle, are observed for [90/−45]s layup on the mold with the highest radius of curvature.
    • Download: (1.443Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      In Situ Investigation of the Kinematics of Ply Interfaces During Composite Manufacturing

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4276130
    Collections
    • Journal of Manufacturing Science and Engineering

    Show full item record

    contributor authorChava, Sandeep
    contributor authorNamilae, Sirish
    date accessioned2022-02-05T21:40:59Z
    date available2022-02-05T21:40:59Z
    date copyright10/7/2020 12:00:00 AM
    date issued2020
    identifier issn1087-1357
    identifier othermanu_143_2_021006.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4276130
    description abstractThe kinematics of composite ply interfaces critically affects both the manufacturing processes and deformation mechanisms and is often responsible for the formation of defects such as wrinkles and delamination. In the present work, processing-induced defects in a carbon fiber prepreg composite are evaluated by devising a novel in situ experimental approach. Carbon fiber prepreg laminates are cured in a specially designed autoclave with viewports with plies laid up on a mold with cylindrical tooling set up to maximize the ply-movement. Four-ply layup orientations of [90/90]s, [90/0]s, [90/45]s, and [90/−45]s and three-mold configurations with cylindrical tools of diameter 9.5 mm (3/8 in.), 12.7 mm (1/2 in.), and 15.9 mm (5/8 in.) are used for the parametric study. Strains, ply-movement, and formation of defects are observed in situ using digital image correlation (DIC) during the autoclave cure cycle, through the viewports. The processing-induced defects in the composite are further characterized by X-ray micro-computed tomography (micro-CT). We observed that the mold with the larger radius of curvature (15.9 mm cylinder) leads to higher strains in both in-plane directions and higher displacement in out of plane directions. The maximum average out-of-plane ply movement, as well as the largest wrinkle, are observed for [90/−45]s layup on the mold with the highest radius of curvature.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleIn Situ Investigation of the Kinematics of Ply Interfaces During Composite Manufacturing
    typeJournal Paper
    journal volume143
    journal issue2
    journal titleJournal of Manufacturing Science and Engineering
    identifier doi10.1115/1.4047740
    journal fristpage021006-1
    journal lastpage021006-10
    page10
    treeJournal of Manufacturing Science and Engineering:;2020:;volume( 143 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian