    Archive

    A Novel Kinematic Model of the Tibiofemoral Joint Based on a Parallel Mechanism

    Source: Journal of Biomechanical Engineering:;2021:;volume( 143 ):;issue: 006::page 061004-1
    Author:
    Arredondo-Soto, Mauricio
    ,
    García-Murillo, Mario A.
    ,
    Vidal-Lesso, Agustín
    ,
    Jesús Cervantes-Sánchez, J.
    ,
    Moreno, Hector A.
    DOI: 10.1115/1.4050034
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: This paper presents a complete kinematic model of the tibiofemoral joint (TFJ) based on a RRPP + 4-SPS parallel mechanism, where R, P, and S stand for revolute, prismatic, and spherical joints, respectively. The model accounts for the contact between tibia and femur, and the four major ligaments: anterior cruciate, posterior cruciate, medial collateral, and lateral collateral, with anatomical significance in their length variations. An experimental flexion passive motion task is performed, and the kinematic model is tested to determine its capability to reproduce the workspace of the motion task. In addition, an optimization process is performed to simulate prescribed ligament length variations during the motion task. The proposed kinematic model is capable to reproduce with high accuracy an experimental three-dimensional workspace, and at the same time, to simulate prescribed ligament length variation during the spatial flexion task. Prescribed ligament length variations are achieved through an optimization process of the ligament insertion points. This model can be used to improve the multibody kinematic optimization (MKO) process during gait analysis, and also in the design of rehabilitation devices as well as trajectories to accelerate the recovery of injured ligaments. The model shows potential to predict ligament length variations during different motion tasks, and can serve as a basis to develop complex models for kinetostatic and dynamic analyses without dealing with computationally expensive models.
    • Download: (1.629Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      A Novel Kinematic Model of the Tibiofemoral Joint Based on a Parallel Mechanism

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4276068
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorArredondo-Soto, Mauricio
    contributor authorGarcía-Murillo, Mario A.
    contributor authorVidal-Lesso, Agustín
    contributor authorJesús Cervantes-Sánchez, J.
    contributor authorMoreno, Hector A.
    date accessioned2022-02-05T21:39:14Z
    date available2022-02-05T21:39:14Z
    date copyright3/12/2021 12:00:00 AM
    date issued2021
    identifier issn0148-0731
    identifier otherbio_143_06_061004.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4276068
    description abstractThis paper presents a complete kinematic model of the tibiofemoral joint (TFJ) based on a RRPP + 4-SPS parallel mechanism, where R, P, and S stand for revolute, prismatic, and spherical joints, respectively. The model accounts for the contact between tibia and femur, and the four major ligaments: anterior cruciate, posterior cruciate, medial collateral, and lateral collateral, with anatomical significance in their length variations. An experimental flexion passive motion task is performed, and the kinematic model is tested to determine its capability to reproduce the workspace of the motion task. In addition, an optimization process is performed to simulate prescribed ligament length variations during the motion task. The proposed kinematic model is capable to reproduce with high accuracy an experimental three-dimensional workspace, and at the same time, to simulate prescribed ligament length variation during the spatial flexion task. Prescribed ligament length variations are achieved through an optimization process of the ligament insertion points. This model can be used to improve the multibody kinematic optimization (MKO) process during gait analysis, and also in the design of rehabilitation devices as well as trajectories to accelerate the recovery of injured ligaments. The model shows potential to predict ligament length variations during different motion tasks, and can serve as a basis to develop complex models for kinetostatic and dynamic analyses without dealing with computationally expensive models.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleA Novel Kinematic Model of the Tibiofemoral Joint Based on a Parallel Mechanism
    typeJournal Paper
    journal volume143
    journal issue6
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.4050034
    journal fristpage061004-1
    journal lastpage061004-10
    page10
    treeJournal of Biomechanical Engineering:;2021:;volume( 143 ):;issue: 006
    contenttypeFulltext