YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    •   YE&T Library
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Trueness of Fit of Biphasic Transversely Isotropic Parameters Model in the Porcine Temporomandibular Joint Disc and Mandibular Condylar Cartilage and Regional Dependence

    Source: Journal of Biomechanical Engineering:;2020:;volume( 142 ):;issue: 008::page 081010-1
    Author:
    Chin, Adam R.
    ,
    Almarza, Alejandro J.
    DOI: 10.1115/1.4046922
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Temporomandibular joint (TMJ) disorders (TMDs) are not well understood and the mechanical differences between the regions of the mandibular condylar cartilage (MCC) and the TMJ disc have not been thoroughly compared. As of now, there are no commercially available regenerative therapies for the TMJ. Elucidating the mechanical properties of these two structures of the articulating joint will help future efforts in developing tissue engineering treatments of the TMJ. In this study, we evaluate the compressive properties of the porcine disc and mandibular condylar cartilage by performing unconfined compression at 10% strain with 4.5%/min strain rate. Punches (4 mm biopsy) from both tissues were taken from five different regions of both the MCC and TMJ: anterior, posterior, lateral, medial, and central. Previously, theoretical models of compression in the porcine tissue did not fit the whole ramp-relaxation behavior. Thus, the data stress–relaxation was fitted to the biphasic transversely isotropic model, for both the TMJ disc and cartilage. From the results found in the disc, it was found that the posterior region had the highest values in multiple viscoelastic parameters when compared to the other regions. The mandibular condylar cartilage was only found to be significantly different in the transverse modulus between the posterior and lateral regions. Both the TMJ disc and MCC had similar magnitudes of values (for the modulus and other corresponding compressive properties) and behavior under this testing modality.
    • Download: (1.147Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Trueness of Fit of Biphasic Transversely Isotropic Parameters Model in the Porcine Temporomandibular Joint Disc and Mandibular Condylar Cartilage and Regional Dependence

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4274530
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorChin, Adam R.
    contributor authorAlmarza, Alejandro J.
    date accessioned2022-02-04T21:55:08Z
    date available2022-02-04T21:55:08Z
    date copyright7/6/2020 12:00:00 AM
    date issued2020
    identifier issn0148-0731
    identifier otherbio_142_08_081010.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4274530
    description abstractTemporomandibular joint (TMJ) disorders (TMDs) are not well understood and the mechanical differences between the regions of the mandibular condylar cartilage (MCC) and the TMJ disc have not been thoroughly compared. As of now, there are no commercially available regenerative therapies for the TMJ. Elucidating the mechanical properties of these two structures of the articulating joint will help future efforts in developing tissue engineering treatments of the TMJ. In this study, we evaluate the compressive properties of the porcine disc and mandibular condylar cartilage by performing unconfined compression at 10% strain with 4.5%/min strain rate. Punches (4 mm biopsy) from both tissues were taken from five different regions of both the MCC and TMJ: anterior, posterior, lateral, medial, and central. Previously, theoretical models of compression in the porcine tissue did not fit the whole ramp-relaxation behavior. Thus, the data stress–relaxation was fitted to the biphasic transversely isotropic model, for both the TMJ disc and cartilage. From the results found in the disc, it was found that the posterior region had the highest values in multiple viscoelastic parameters when compared to the other regions. The mandibular condylar cartilage was only found to be significantly different in the transverse modulus between the posterior and lateral regions. Both the TMJ disc and MCC had similar magnitudes of values (for the modulus and other corresponding compressive properties) and behavior under this testing modality.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleTrueness of Fit of Biphasic Transversely Isotropic Parameters Model in the Porcine Temporomandibular Joint Disc and Mandibular Condylar Cartilage and Regional Dependence
    typeJournal Paper
    journal volume142
    journal issue8
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.4046922
    journal fristpage081010-1
    journal lastpage081010-8
    page8
    treeJournal of Biomechanical Engineering:;2020:;volume( 142 ):;issue: 008
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian