YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    •   YE&T Library
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    On the Connection Between Geometry and Statically Determined Membrane Stresses in the Human Cornea

    Source: Journal of Biomechanical Engineering:;2020:;volume( 142 ):;issue: 005
    Author:
    Angelillo, M.
    ,
    Montanino, A.
    ,
    Pandolfi, A.
    DOI: 10.1115/1.4044742
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Under the action of the intraocular pressure (IOP), the human cornea is stressed and deforms acquiring a quasi-spherical configuration. If the stressed configuration is known, and the cornea is regarded as a membrane, disregarding flexural behaviors with an equilibrium analysis only is possible to estimate the distribution of the average stress across the thickness. In the cornea, the action of the intraocular pressure is supported by collagen fibrils, immersed into an elastin-proteoglycan matrix, and organized in a very precise architecture to provide the necessary confinement and transparency to the light. With the goal of understanding the static consequences of shape modifications due to pathological dilatation (ectasia), we present a simplified stress analysis of the human cornea modeled as a membrane. A numerical investigation over 40 patient-specific corneas (20 normal and 20 ectatic) is carried out to establish a relationship between the physiological geometry and the distribution of the membrane stresses, and to assess the possibility to obtain information on the stress state based on topographic images only. Comparative analyses reveal that, with respect to normal corneas, in ectatic corneas the pattern of the principal stress lines is modified markedly showing a deviation from the hypothetical dominant orientation of the collagen fibrils. The rotation of the principal stress with respect to the fibril orientation can be thought as responsible of the transmission of a large amount of shear stresses onto the elastin-proteoglycan matrix. The anomalous loading of the matrix could be correlated to the evolution of time-dependent shape modifications leading to ectasia.
    • Download: (4.391Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      On the Connection Between Geometry and Statically Determined Membrane Stresses in the Human Cornea

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4274372
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorAngelillo, M.
    contributor authorMontanino, A.
    contributor authorPandolfi, A.
    date accessioned2022-02-04T14:47:24Z
    date available2022-02-04T14:47:24Z
    date copyright2020/01/20/
    date issued2020
    identifier issn0148-0731
    identifier otherbio_142_05_051006.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4274372
    description abstractUnder the action of the intraocular pressure (IOP), the human cornea is stressed and deforms acquiring a quasi-spherical configuration. If the stressed configuration is known, and the cornea is regarded as a membrane, disregarding flexural behaviors with an equilibrium analysis only is possible to estimate the distribution of the average stress across the thickness. In the cornea, the action of the intraocular pressure is supported by collagen fibrils, immersed into an elastin-proteoglycan matrix, and organized in a very precise architecture to provide the necessary confinement and transparency to the light. With the goal of understanding the static consequences of shape modifications due to pathological dilatation (ectasia), we present a simplified stress analysis of the human cornea modeled as a membrane. A numerical investigation over 40 patient-specific corneas (20 normal and 20 ectatic) is carried out to establish a relationship between the physiological geometry and the distribution of the membrane stresses, and to assess the possibility to obtain information on the stress state based on topographic images only. Comparative analyses reveal that, with respect to normal corneas, in ectatic corneas the pattern of the principal stress lines is modified markedly showing a deviation from the hypothetical dominant orientation of the collagen fibrils. The rotation of the principal stress with respect to the fibril orientation can be thought as responsible of the transmission of a large amount of shear stresses onto the elastin-proteoglycan matrix. The anomalous loading of the matrix could be correlated to the evolution of time-dependent shape modifications leading to ectasia.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleOn the Connection Between Geometry and Statically Determined Membrane Stresses in the Human Cornea
    typeJournal Paper
    journal volume142
    journal issue5
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.4044742
    page51006
    treeJournal of Biomechanical Engineering:;2020:;volume( 142 ):;issue: 005
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian