    Biomechanical Comparison of a New Dynamic Ankle Orthosis to a Standard Ankle-Foot Orthosis During Walking

    Source: Journal of Biomechanical Engineering:;2020:;volume( 142 ):;issue: 005
    Author:
    Chung, Chloe L.
    ,
    DiAngelo, Denis J.
    ,
    Powell, Douglas W.
    ,
    Paquette, Max R.
    DOI: 10.1115/1.4045549
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Patients who sustain irreversible cartilage damage or joint instability from ankle injuries are likely to develop ankle osteoarthritis (OA). A dynamic ankle orthosis (DAO) was recently designed with the intent to offload the foot and ankle using a distractive force, allowing more natural sagittal and frontal plane ankle motion during gait. To evaluate its efficacy, this study compared ankle joint kinematics and plantar pressures among the DAO, standard double upright ankle-foot orthosis (DUAFO), and a nonorthosis control (CON) condition in healthy adults during walking. Ten healthy subjects (26 ± 3.8 yr; 69.6 ± 12.7 kg; and 1.69 ± 0.07 m) walked on a treadmill at 1.4 m/s in three orthosis conditions: CON, DAO, and DUAFO. Ankle kinematics were assessed using a three-dimensional (3D) motion capture system and in-shoe plantar pressures were measured for seven areas of the foot. DAO reduced hallux peak plantar pressures (PPs) compared to CON and DUAFO. PPs under toes 2–5 were smaller in DAO than DUAFO, but greater in DUAFO compared to CON. Early stance peak plantarflexion (PF) angular velocity was smaller in DAO compared to CON and DUAFO. Eversion (EV) ROM was much smaller in DUAFO compared to CON and DAO. Early stance peak eversion angular velocity was smaller in DAO and much smaller in DUAFO compared to CON. This study demonstrates the capacity of the DAO to provide offloading during ambulation without greatly affecting kinematic parameters including frontal plane ankle motion compared to CON. Future work will assess the effectiveness of the DAO in a clinical osteoarthritic population.
    • Download: (1.303Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Biomechanical Comparison of a New Dynamic Ankle Orthosis to a Standard Ankle-Foot Orthosis During Walking

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4274347
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorChung, Chloe L.
    contributor authorDiAngelo, Denis J.
    contributor authorPowell, Douglas W.
    contributor authorPaquette, Max R.
    date accessioned2022-02-04T14:46:37Z
    date available2022-02-04T14:46:37Z
    date copyright2020/01/17/
    date issued2020
    identifier issn0148-0731
    identifier otherbio_142_05_051003.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4274347
    description abstractPatients who sustain irreversible cartilage damage or joint instability from ankle injuries are likely to develop ankle osteoarthritis (OA). A dynamic ankle orthosis (DAO) was recently designed with the intent to offload the foot and ankle using a distractive force, allowing more natural sagittal and frontal plane ankle motion during gait. To evaluate its efficacy, this study compared ankle joint kinematics and plantar pressures among the DAO, standard double upright ankle-foot orthosis (DUAFO), and a nonorthosis control (CON) condition in healthy adults during walking. Ten healthy subjects (26 ± 3.8 yr; 69.6 ± 12.7 kg; and 1.69 ± 0.07 m) walked on a treadmill at 1.4 m/s in three orthosis conditions: CON, DAO, and DUAFO. Ankle kinematics were assessed using a three-dimensional (3D) motion capture system and in-shoe plantar pressures were measured for seven areas of the foot. DAO reduced hallux peak plantar pressures (PPs) compared to CON and DUAFO. PPs under toes 2–5 were smaller in DAO than DUAFO, but greater in DUAFO compared to CON. Early stance peak plantarflexion (PF) angular velocity was smaller in DAO compared to CON and DUAFO. Eversion (EV) ROM was much smaller in DUAFO compared to CON and DAO. Early stance peak eversion angular velocity was smaller in DAO and much smaller in DUAFO compared to CON. This study demonstrates the capacity of the DAO to provide offloading during ambulation without greatly affecting kinematic parameters including frontal plane ankle motion compared to CON. Future work will assess the effectiveness of the DAO in a clinical osteoarthritic population.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleBiomechanical Comparison of a New Dynamic Ankle Orthosis to a Standard Ankle-Foot Orthosis During Walking
    typeJournal Paper
    journal volume142
    journal issue5
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.4045549
    page51003
    treeJournal of Biomechanical Engineering:;2020:;volume( 142 ):;issue: 005
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian