    Revisiting the Basis for Hip Fracture Prediction Through Bone Mineral Density Scans: Large Potential Errors and Improved Methods

    Source: Journal of Engineering and Science in Medical Diagnostics and Therapy:;2020:;volume( 003 ):;issue: 003
    Author:
    Munsell, Jr., W. P.
    DOI: 10.1115/1.4046927
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Researchers have attempted to evaluate the likelihood of hip fracture as a function of an engineering concept called the moment of inertia, as applied to the cross-sectional area of hip bones. While the premise is sound, the results have been disappointing. Although several authors have acknowledged that errors may arise in the current methods investigators employ to determine the cross section moment of inertia (CSMI), none have looked critically at the sources, or even the magnitude, of those errors. This paper evaluates the nature of the error that can be introduced by the use of one-dimensional bone mineral density scans to estimate the CSMI and quantifies its impact on predictive calculations. In addition, this paper presents an improved method for approximating the mechanical section properties of highly complex cross sections. The factors affecting the accuracy of the proposed method are tested, and its error rate is also quantified. The method employs a two-dimensional analysis of digital images of the subject cross section and does not require extensive user expertise or investment in expensive finite element analysis programs to implement. The limited file space necessary to install the required code means that standard smart phones could be used to directly evaluate the most complex cross section in the field.
    • Download: (708.3Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Revisiting the Basis for Hip Fracture Prediction Through Bone Mineral Density Scans: Large Potential Errors and Improved Methods

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4273802
    Collections
    • Journal of Engineering and Science in Medical Diagnostics and Therapy

    Show full item record

    contributor authorMunsell, Jr., W. P.
    date accessioned2022-02-04T14:30:30Z
    date available2022-02-04T14:30:30Z
    date copyright2020/05/05/
    date issued2020
    identifier issn2572-7958
    identifier otherjesmdt_003_03_031003.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4273802
    description abstractResearchers have attempted to evaluate the likelihood of hip fracture as a function of an engineering concept called the moment of inertia, as applied to the cross-sectional area of hip bones. While the premise is sound, the results have been disappointing. Although several authors have acknowledged that errors may arise in the current methods investigators employ to determine the cross section moment of inertia (CSMI), none have looked critically at the sources, or even the magnitude, of those errors. This paper evaluates the nature of the error that can be introduced by the use of one-dimensional bone mineral density scans to estimate the CSMI and quantifies its impact on predictive calculations. In addition, this paper presents an improved method for approximating the mechanical section properties of highly complex cross sections. The factors affecting the accuracy of the proposed method are tested, and its error rate is also quantified. The method employs a two-dimensional analysis of digital images of the subject cross section and does not require extensive user expertise or investment in expensive finite element analysis programs to implement. The limited file space necessary to install the required code means that standard smart phones could be used to directly evaluate the most complex cross section in the field.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleRevisiting the Basis for Hip Fracture Prediction Through Bone Mineral Density Scans: Large Potential Errors and Improved Methods
    typeJournal Paper
    journal volume3
    journal issue3
    journal titleJournal of Engineering and Science in Medical Diagnostics and Therapy
    identifier doi10.1115/1.4046927
    page31003
    treeJournal of Engineering and Science in Medical Diagnostics and Therapy:;2020:;volume( 003 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian