    Optimization of Fin Parameters to Reduce Entropy Generation and Melting Time of a Latent Heat Storage Unit

    Source: Journal of Solar Energy Engineering:;2020:;volume( 142 ):;issue: 006
    Author:
    Kalapala, Lokesh
    ,
    Devanuri, Jaya Krishna
    DOI: 10.1115/1.4046878
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: One of the challenges in the design and development of a latent heat storage unit (LHSU) is to increase the charging and discharging rates which are inherently low because of low thermal conductivity of phase change materials (PCM). Out of various heat transfer enhancement techniques, employing annular fins is very simple, efficient and no fabrication complexity is involved. Fin parameters (fin size and number of fins) significantly influence the enhancement in heat transfer rate. Hence, optimization of fin parameters is necessary for the efficient design of an LHSU. While designing an LHSU along with heat transfer rate, entropy generation should also be considered in order to make it exergetically efficient. Therefore, the present study is aimed at multi-objective optimization of annular fin parameters to minimize the melting time and entropy generation. Fin diameter and the number of fins are taken as the variables. The influence of these two variables on the melting time, average Nusselt number, energy stored, and distribution of entropy is presented. The melting rate is increased, and global entropy generation decreased by increasing the number of fins up to 15. An increase in the fin diameter reduced the melting time while entropy generation got increased. For the multi-objective optimization, the multi-objective optimization based on ratio analysis (MOORA) technique is chosen and the optimized values of fin diameter and number of fins are observed to be 80 mm and 15 respectively. Finally, optimized parameters are represented in non-dimensional form to make them applicable for any size of the LHSU.
    • Download: (1.360Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Optimization of Fin Parameters to Reduce Entropy Generation and Melting Time of a Latent Heat Storage Unit

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4273170
    Collections
    • Journal of Solar Energy Engineering

    Show full item record

    contributor authorKalapala, Lokesh
    contributor authorDevanuri, Jaya Krishna
    date accessioned2022-02-04T14:12:06Z
    date available2022-02-04T14:12:06Z
    date copyright2020/05/05/
    date issued2020
    identifier issn0199-6231
    identifier othersol_142_6_061005.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4273170
    description abstractOne of the challenges in the design and development of a latent heat storage unit (LHSU) is to increase the charging and discharging rates which are inherently low because of low thermal conductivity of phase change materials (PCM). Out of various heat transfer enhancement techniques, employing annular fins is very simple, efficient and no fabrication complexity is involved. Fin parameters (fin size and number of fins) significantly influence the enhancement in heat transfer rate. Hence, optimization of fin parameters is necessary for the efficient design of an LHSU. While designing an LHSU along with heat transfer rate, entropy generation should also be considered in order to make it exergetically efficient. Therefore, the present study is aimed at multi-objective optimization of annular fin parameters to minimize the melting time and entropy generation. Fin diameter and the number of fins are taken as the variables. The influence of these two variables on the melting time, average Nusselt number, energy stored, and distribution of entropy is presented. The melting rate is increased, and global entropy generation decreased by increasing the number of fins up to 15. An increase in the fin diameter reduced the melting time while entropy generation got increased. For the multi-objective optimization, the multi-objective optimization based on ratio analysis (MOORA) technique is chosen and the optimized values of fin diameter and number of fins are observed to be 80 mm and 15 respectively. Finally, optimized parameters are represented in non-dimensional form to make them applicable for any size of the LHSU.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleOptimization of Fin Parameters to Reduce Entropy Generation and Melting Time of a Latent Heat Storage Unit
    typeJournal Paper
    journal volume142
    journal issue6
    journal titleJournal of Solar Energy Engineering
    identifier doi10.1115/1.4046878
    page61005
    treeJournal of Solar Energy Engineering:;2020:;volume( 142 ):;issue: 006
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian