    Evaluation of Steel Fiber–Reinforced Sprayed Concrete by Energy Absorption Tests

    Source: Journal of Materials in Civil Engineering:;2021:;Volume ( 033 ):;issue: 009::page 04021252-1
    Author:
    Alan Renato Estrada Cáceres
    ,
    Sergio Henrique Pialarissi Cavalaro
    ,
    Antonio Domingues de Figueiredo
    DOI: 10.1061/(ASCE)MT.1943-5533.0003865
    Publisher: ASCE
    Abstract: Steel fiber–reinforced sprayed concrete (SFRSC) is widely used for ground support in underground works. The panel test, as in EN 14488-5, is one of the most common procedures for the quality control of the energy absorption capacity of SFRSC. The test entails the use of large equipment to manipulate and characterize heavy specimens that cannot be easily extracted from a structure in case a direct assessment of the material in place is needed. Alternative procedures, such as the Barcelona test (BCN), have been used to assess the energy absorption of cast fiber–reinforced concrete in smaller-scale cylindrical specimens that can be extracted from a structure and are considerably less demanding in terms of equipment and payload. The objective of this study is to evaluate the use of the BCN as a substitution of the traditional square panel test to assess the energy absorption of SFRSC. Both tests were conducted in parallel in combination with the quantification of the incorporated fiber content through an inductive test. Hence, the analysis reflects the actual control conditions of the SFRSC under the influence of spraying. Results indicate a possible reliable correlation between the BCN and panel test if the cracked area is considered. Different sizes of cores were tested to understand the influence of this parameter in energy absorption by the BCN test. The reduction of specimen size demands an increase in the number of determinations per batch to ensure representative results. The study suggests that the BCN can be considered a viable method of evaluating the energy absorption of SFRSC in cores extracted from test panels or actual tunnel linings.
    • Download: (1.964Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Evaluation of Steel Fiber–Reinforced Sprayed Concrete by Energy Absorption Tests

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4272529
    Collections
    • Journal of Materials in Civil Engineering

    Show full item record

    contributor authorAlan Renato Estrada Cáceres
    contributor authorSergio Henrique Pialarissi Cavalaro
    contributor authorAntonio Domingues de Figueiredo
    date accessioned2022-02-01T22:03:32Z
    date available2022-02-01T22:03:32Z
    date issued9/1/2021
    identifier other%28ASCE%29MT.1943-5533.0003865.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4272529
    description abstractSteel fiber–reinforced sprayed concrete (SFRSC) is widely used for ground support in underground works. The panel test, as in EN 14488-5, is one of the most common procedures for the quality control of the energy absorption capacity of SFRSC. The test entails the use of large equipment to manipulate and characterize heavy specimens that cannot be easily extracted from a structure in case a direct assessment of the material in place is needed. Alternative procedures, such as the Barcelona test (BCN), have been used to assess the energy absorption of cast fiber–reinforced concrete in smaller-scale cylindrical specimens that can be extracted from a structure and are considerably less demanding in terms of equipment and payload. The objective of this study is to evaluate the use of the BCN as a substitution of the traditional square panel test to assess the energy absorption of SFRSC. Both tests were conducted in parallel in combination with the quantification of the incorporated fiber content through an inductive test. Hence, the analysis reflects the actual control conditions of the SFRSC under the influence of spraying. Results indicate a possible reliable correlation between the BCN and panel test if the cracked area is considered. Different sizes of cores were tested to understand the influence of this parameter in energy absorption by the BCN test. The reduction of specimen size demands an increase in the number of determinations per batch to ensure representative results. The study suggests that the BCN can be considered a viable method of evaluating the energy absorption of SFRSC in cores extracted from test panels or actual tunnel linings.
    publisherASCE
    titleEvaluation of Steel Fiber–Reinforced Sprayed Concrete by Energy Absorption Tests
    typeJournal Paper
    journal volume33
    journal issue9
    journal titleJournal of Materials in Civil Engineering
    identifier doi10.1061/(ASCE)MT.1943-5533.0003865
    journal fristpage04021252-1
    journal lastpage04021252-11
    page11
    treeJournal of Materials in Civil Engineering:;2021:;Volume ( 033 ):;issue: 009
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian