    Cost Analysis of Annual and Monthly Net Zero Energy Performance for Multifamily Buildings in the United States

    Source: Journal of Architectural Engineering:;2021:;Volume ( 027 ):;issue: 002::page 04021003-1
    Author:
    Adam R. McKittrick
    ,
    Gregor P. Henze
    DOI: 10.1061/(ASCE)AE.1943-5568.0000453
    Publisher: ASCE
    Abstract: As the United States continues its progress toward sustainable construction, net zero building design is becoming an increasingly important and popular topic. Two definitions of net zero energy performance, monthly and annual, provide different levels of energy autonomy and efficiency within a building. This article analyzes the viability and incremental cost for two-, three-, and four-story multifamily apartment buildings to reach both annual and monthly net zero energy performance throughout four climate zones in the United States using baseline reference buildings that represent current construction practices. Building size plays a large role in determining the capability for a building model to reach annual or monthly net zero. Two-story buildings are capable of reaching annual net zero with an increase in construction cost of about 4.4–5.6%. Three-story buildings in warmer climates can achieve annual net zero with an increase of about 5.1%, but models in colder climates cannot reach annual net zero performance. Four-story buildings cannot achieve net zero, owing to insufficient building area for solar arrays to produce electricity. Monthly net zero energy performance was significantly harder to achieve, with the only case reaching this goal being the two-story Houston based model, at an added cost of 8.2%. Generally speaking, only small buildings in warm climates will be able to achieve monthly net zero without vastly oversizing photovoltaic systems and increasing costs without adequate payback.
    • Download: (1.861Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Cost Analysis of Annual and Monthly Net Zero Energy Performance for Multifamily Buildings in the United States

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4271525
    Collections
    • Journal of Architectural Engineering

    Show full item record

    contributor authorAdam R. McKittrick
    contributor authorGregor P. Henze
    date accessioned2022-02-01T00:29:53Z
    date available2022-02-01T00:29:53Z
    date issued6/1/2021
    identifier other%28ASCE%29AE.1943-5568.0000453.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4271525
    description abstractAs the United States continues its progress toward sustainable construction, net zero building design is becoming an increasingly important and popular topic. Two definitions of net zero energy performance, monthly and annual, provide different levels of energy autonomy and efficiency within a building. This article analyzes the viability and incremental cost for two-, three-, and four-story multifamily apartment buildings to reach both annual and monthly net zero energy performance throughout four climate zones in the United States using baseline reference buildings that represent current construction practices. Building size plays a large role in determining the capability for a building model to reach annual or monthly net zero. Two-story buildings are capable of reaching annual net zero with an increase in construction cost of about 4.4–5.6%. Three-story buildings in warmer climates can achieve annual net zero with an increase of about 5.1%, but models in colder climates cannot reach annual net zero performance. Four-story buildings cannot achieve net zero, owing to insufficient building area for solar arrays to produce electricity. Monthly net zero energy performance was significantly harder to achieve, with the only case reaching this goal being the two-story Houston based model, at an added cost of 8.2%. Generally speaking, only small buildings in warm climates will be able to achieve monthly net zero without vastly oversizing photovoltaic systems and increasing costs without adequate payback.
    publisherASCE
    titleCost Analysis of Annual and Monthly Net Zero Energy Performance for Multifamily Buildings in the United States
    typeJournal Paper
    journal volume27
    journal issue2
    journal titleJournal of Architectural Engineering
    identifier doi10.1061/(ASCE)AE.1943-5568.0000453
    journal fristpage04021003-1
    journal lastpage04021003-17
    page17
    treeJournal of Architectural Engineering:;2021:;Volume ( 027 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian