| contributor author | Mariusz Zych | |
| contributor author | Trong-Chuc Nguyen | |
| date accessioned | 2022-02-01T00:06:31Z | |
| date available | 2022-02-01T00:06:31Z | |
| date issued | 8/1/2021 | |
| identifier other | %28ASCE%29CF.1943-5509.0001585.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl1/handle/yetl/4270930 | |
| description abstract | Semimassive tanks must satisfy the requirement of watertightness, so all attempts to reduce early-age imposed strains lead to considerable financial savings. The impact of a cooling pipe system (CPS) on a reinforced concrete (RC) tank wall where early-age cracks developed during construction has been analyzed. It has been proven that for RC tanks, the factor that contributes most to tensile stresses in the semimassive walls is the mean temperature of the maturing concrete. The second most influential factor is derived from self-stresses, and the least influential factor is the stress gradient. The calculations of self-stresses indicate that the use of a CPS leads to the formation of favorable compressive rather than tensile stresses in the central part of the wall. Most importantly, a CPS in RC tank walls significantly reduces the width of cracks that result from the cumulative effect of early-age and long-term imposed strains. The performed analysis provides a basis for the effective design of a CPS in RC tank semimassive walls. | |
| publisher | ASCE | |
| title | Early Age Cracking Control in Semimassive Walls of RC Tanks by Internal Cooling | |
| type | Journal Paper | |
| journal volume | 35 | |
| journal issue | 4 | |
| journal title | Journal of Performance of Constructed Facilities | |
| identifier doi | 10.1061/(ASCE)CF.1943-5509.0001585 | |
| journal fristpage | 04021022-1 | |
| journal lastpage | 04021022-10 | |
| page | 10 | |
| tree | Journal of Performance of Constructed Facilities:;2021:;Volume ( 035 ):;issue: 004 | |
| contenttype | Fulltext | |