    Torsional Behavior of Circular Concrete-Filled FRP Tubes

    Source: Journal of Composites for Construction:;2021:;Volume ( 025 ):;issue: 003::page 04021013-1
    Author:
    James St. Onge
    ,
    Amir Fam
    DOI: 10.1061/(ASCE)CC.1943-5614.0001122
    Publisher: ASCE
    Abstract: Concrete-filled fiber-reinforced polymer (FRP) tubes (CFFTs) have been studied extensively under almost all loading conditions, except torsion. In this pioneering study, six 168-mm-diameter samples were tested in pure torsion, consisting of two hollow glass-FRP tubes and four CFFTs. Two tubes with distinctly different laminate structures were tested and compared, namely, near-cross-ply and angle-ply tubes. A specially designed Z-shape setup with unique features intended to avoid second-order effects and facilitate gripping of the circular section was developed and used to apply pure torsion. The results showed that the postcracking response was heavily dependent on the FRP tube laminate structure. The tube confined the concrete core diagonal struts, as evident by a state of combined stresses in the tube, which ultimately fractured. The concrete core prevented buckling of the tubes and resulted in a 250% increase in ultimate torques over the hollow tubes. It also increased twist angles by 14% and 45% for CFFTs with near-cross-ply and angle-ply tubes, respectively. The angle-ply CFFT achieved a 118% increase in ultimate torque but was 48% lower in ultimate twist, compared to the near-cross-ply CFFT, with the latter showing a significant nonlinear response. A simplified analytical model based on the superposition of the truss action and membrane shear action of the tube was developed and verified. It was then used in a parametric study to examine the effect of the laminate structure and tube thickness on torsional strength, ranging from the lower bound based on the [0°/90°]s cross-ply tube to the upper bound based on the [±45°]s angle-ply tube.
    • Download: (2.711Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Torsional Behavior of Circular Concrete-Filled FRP Tubes

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4270874
    Collections
    • Journal of Composites for Construction

    Show full item record

    contributor authorJames St. Onge
    contributor authorAmir Fam
    date accessioned2022-02-01T00:04:36Z
    date available2022-02-01T00:04:36Z
    date issued6/1/2021
    identifier other%28ASCE%29CC.1943-5614.0001122.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4270874
    description abstractConcrete-filled fiber-reinforced polymer (FRP) tubes (CFFTs) have been studied extensively under almost all loading conditions, except torsion. In this pioneering study, six 168-mm-diameter samples were tested in pure torsion, consisting of two hollow glass-FRP tubes and four CFFTs. Two tubes with distinctly different laminate structures were tested and compared, namely, near-cross-ply and angle-ply tubes. A specially designed Z-shape setup with unique features intended to avoid second-order effects and facilitate gripping of the circular section was developed and used to apply pure torsion. The results showed that the postcracking response was heavily dependent on the FRP tube laminate structure. The tube confined the concrete core diagonal struts, as evident by a state of combined stresses in the tube, which ultimately fractured. The concrete core prevented buckling of the tubes and resulted in a 250% increase in ultimate torques over the hollow tubes. It also increased twist angles by 14% and 45% for CFFTs with near-cross-ply and angle-ply tubes, respectively. The angle-ply CFFT achieved a 118% increase in ultimate torque but was 48% lower in ultimate twist, compared to the near-cross-ply CFFT, with the latter showing a significant nonlinear response. A simplified analytical model based on the superposition of the truss action and membrane shear action of the tube was developed and verified. It was then used in a parametric study to examine the effect of the laminate structure and tube thickness on torsional strength, ranging from the lower bound based on the [0°/90°]s cross-ply tube to the upper bound based on the [±45°]s angle-ply tube.
    publisherASCE
    titleTorsional Behavior of Circular Concrete-Filled FRP Tubes
    typeJournal Paper
    journal volume25
    journal issue3
    journal titleJournal of Composites for Construction
    identifier doi10.1061/(ASCE)CC.1943-5614.0001122
    journal fristpage04021013-1
    journal lastpage04021013-15
    page15
    treeJournal of Composites for Construction:;2021:;Volume ( 025 ):;issue: 003
    contenttypeFulltext