    New Slenderness Limitations for Shear Strength Estimation of Reinforced Concrete Walls

    Source: Practice Periodical on Structural Design and Construction:;2021:;Volume ( 026 ):;issue: 001::page 04020066-1
    Author:
    Rabab Allouzi
    DOI: 10.1061/(ASCE)SC.1943-5576.0000554
    Publisher: ASCE
    Abstract: This article suggests a new practical method to estimate the nominal shear strength of reinforced concrete (RC) walls. This method identifies whether a specific RC wall is short, slender, or intermediate in height. The aspect ratio (height/length) is a dominant parameter in defining the slenderness of RC walls by many provisions such as the Federal Emergency Management Agency, FEMA 356, in which the aspect ratio of short walls ≤1.5, slender walls ≥3, and intermediate walls valued between 1.5 and 3. In this paper, different aspect ratio limits are proposed to determine the slenderness of RC walls, with short walls being ≤0.5, slender walls >1.5, while intermediate walls are valued in between 0.5 and 1.5. Based on this categorization, the nominal shear strength of short walls is estimated at 75% of the shear capacity calculated based on the American Concrete Institute, ACI 318-14M, for ordinary walls. The shear at nominal flexural strength is considered the nominal shear strength of slender walls. For intermediate walls, a new method is suggested to determine whether shear capacity or shear at nominal flexural strength affects and influences nominal shear strength estimation. To validate this method, the nominal shear strength is estimated as proposed herein for 147 wall specimens experimentally tested by other researchers. The nominal shear strength of these tested walls is calculated based on FEMA 356 provisions and then compared to the results of the proposed method. It is concluded that the proposed method is optimal in estimating the experimental shear strength as compared to FEMA 356.
    • Download: (1.622Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      New Slenderness Limitations for Shear Strength Estimation of Reinforced Concrete Walls

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4270241
    Collections
    • Journal of Structural Design and Construction Practice

    Show full item record

    contributor authorRabab Allouzi
    date accessioned2022-01-31T23:43:35Z
    date available2022-01-31T23:43:35Z
    date issued2/1/2021
    identifier other%28ASCE%29SC.1943-5576.0000554.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4270241
    description abstractThis article suggests a new practical method to estimate the nominal shear strength of reinforced concrete (RC) walls. This method identifies whether a specific RC wall is short, slender, or intermediate in height. The aspect ratio (height/length) is a dominant parameter in defining the slenderness of RC walls by many provisions such as the Federal Emergency Management Agency, FEMA 356, in which the aspect ratio of short walls ≤1.5, slender walls ≥3, and intermediate walls valued between 1.5 and 3. In this paper, different aspect ratio limits are proposed to determine the slenderness of RC walls, with short walls being ≤0.5, slender walls >1.5, while intermediate walls are valued in between 0.5 and 1.5. Based on this categorization, the nominal shear strength of short walls is estimated at 75% of the shear capacity calculated based on the American Concrete Institute, ACI 318-14M, for ordinary walls. The shear at nominal flexural strength is considered the nominal shear strength of slender walls. For intermediate walls, a new method is suggested to determine whether shear capacity or shear at nominal flexural strength affects and influences nominal shear strength estimation. To validate this method, the nominal shear strength is estimated as proposed herein for 147 wall specimens experimentally tested by other researchers. The nominal shear strength of these tested walls is calculated based on FEMA 356 provisions and then compared to the results of the proposed method. It is concluded that the proposed method is optimal in estimating the experimental shear strength as compared to FEMA 356.
    publisherASCE
    titleNew Slenderness Limitations for Shear Strength Estimation of Reinforced Concrete Walls
    typeJournal Paper
    journal volume26
    journal issue1
    journal titlePractice Periodical on Structural Design and Construction
    identifier doi10.1061/(ASCE)SC.1943-5576.0000554
    journal fristpage04020066-1
    journal lastpage04020066-14
    page14
    treePractice Periodical on Structural Design and Construction:;2021:;Volume ( 026 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian