Physical Properties and Seepage Characteristics of Optimized Fiber-Reinforced Permeable ConcreteSource: Journal of Materials in Civil Engineering:;2021:;Volume ( 033 ):;issue: 005::page 04021093-1DOI: 10.1061/(ASCE)MT.1943-5533.0003590Publisher: ASCE
Abstract: Permeable concrete is required to have adequate strength, water permeability, and freeze-thaw resistance as pavement material. The purpose of this research is to improve the properties of fiber-reinforced permeable concrete (FRPC) based on orthogonal experimental design by adjusting water-cement ratio (w/c), target porosity, volume content of polyacrylonitrile fiber (PANF), and polypropylene plastic fiber (PPF). Computer tomography (CT) is applied to generate the three-dimensional (3D) pore structure model of optimized FRPC for permeability prediction and seepage flow simulation by the computed fluid dynamics (CFD) method. The results show that the FRPC with w/c of 0.37, target porosity of 20%, PANF volume content of 0.16%, and PPF volume content of 0.25% can obtain reasonable strength (compressive strength>20 MPa, flexural strength>2.5 MPa), high water permeability (permeability coefficient>20 mm/s), and adequate frost resistance (freeze-thaw cycles>200). The permeability coefficient obtained by numerical simulation shows error less than 10% in comparison with experimental results. The relationship of seepage velocity and pressure gradient confirms to Darcy-Forchheimer’s law and the critical Reynolds number for optimized FRPC with aggregate sizes of 10–15 mm is 21.92.
|
Collections
Show full item record
| contributor author | Fusheng Wen | |
| contributor author | Kunqiang Zhang | |
| contributor author | Huafeng Fan | |
| contributor author | Shengtong Zhai | |
| contributor author | Fusheng Liu | |
| date accessioned | 2022-01-31T23:32:25Z | |
| date available | 2022-01-31T23:32:25Z | |
| date issued | 5/1/2021 | |
| identifier other | %28ASCE%29MT.1943-5533.0003590.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl1/handle/yetl/4269900 | |
| description abstract | Permeable concrete is required to have adequate strength, water permeability, and freeze-thaw resistance as pavement material. The purpose of this research is to improve the properties of fiber-reinforced permeable concrete (FRPC) based on orthogonal experimental design by adjusting water-cement ratio (w/c), target porosity, volume content of polyacrylonitrile fiber (PANF), and polypropylene plastic fiber (PPF). Computer tomography (CT) is applied to generate the three-dimensional (3D) pore structure model of optimized FRPC for permeability prediction and seepage flow simulation by the computed fluid dynamics (CFD) method. The results show that the FRPC with w/c of 0.37, target porosity of 20%, PANF volume content of 0.16%, and PPF volume content of 0.25% can obtain reasonable strength (compressive strength>20 MPa, flexural strength>2.5 MPa), high water permeability (permeability coefficient>20 mm/s), and adequate frost resistance (freeze-thaw cycles>200). The permeability coefficient obtained by numerical simulation shows error less than 10% in comparison with experimental results. The relationship of seepage velocity and pressure gradient confirms to Darcy-Forchheimer’s law and the critical Reynolds number for optimized FRPC with aggregate sizes of 10–15 mm is 21.92. | |
| publisher | ASCE | |
| title | Physical Properties and Seepage Characteristics of Optimized Fiber-Reinforced Permeable Concrete | |
| type | Journal Paper | |
| journal volume | 33 | |
| journal issue | 5 | |
| journal title | Journal of Materials in Civil Engineering | |
| identifier doi | 10.1061/(ASCE)MT.1943-5533.0003590 | |
| journal fristpage | 04021093-1 | |
| journal lastpage | 04021093-12 | |
| page | 12 | |
| tree | Journal of Materials in Civil Engineering:;2021:;Volume ( 033 ):;issue: 005 | |
| contenttype | Fulltext |