    Effect of Construction Deficiencies on Seismic Performance of Hospitals during the 2017 Sarpol-e Zahab Earthquake

    Source: Journal of Performance of Constructed Facilities:;2021:;Volume ( 035 ):;issue: 001::page 04020140
    Author:
    Siavash Sadeghi
    ,
    Afshin Kalantari
    ,
    Esmaeel Izadi Zaman Abadi
    DOI: 10.1061/(ASCE)CF.1943-5509.0001550
    Publisher: ASCE
    Abstract: In this study, the construction deficiencies affecting performance of hospitals during the 2017 Sarpol-e Zahab earthquake in Iran were studied through a field survey and numerical assessment. The inadequate bracing of infill walls, façades, and false ceilings, as well as the improper infill wall materials were the nonstructural deficiencies identified through the initial field survey. Improper spacing and anchoring of the reinforcement, unanticipated frame-infill interaction, and low concrete strength were also identified as the major drawbacks of structural members. In the numerical assessment, the results of the concrete coring tests were utilized to establish an as-built nonlinear model whose response was compared with the as-designed model for evaluation purposes. For this purpose, the models were initially pushed to a target roof drift and were then subjected to nonlinear response history analyses under various levels of the Sarpol-e Zahab earthquake. The ductility demands undergone by some members of the deficient as-built model were shown to surpass the counterpart values of the stronger as-designed model, while a nearly 17% reduction was observed in the maximum base shear due to the construction deficiencies.
    • Download: (3.087Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Effect of Construction Deficiencies on Seismic Performance of Hospitals during the 2017 Sarpol-e Zahab Earthquake

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4269675
    Collections
    • Journal of Performance of Constructed Facilities

    Show full item record

    contributor authorSiavash Sadeghi
    contributor authorAfshin Kalantari
    contributor authorEsmaeel Izadi Zaman Abadi
    date accessioned2022-01-30T22:49:07Z
    date available2022-01-30T22:49:07Z
    date issued2/1/2021
    identifier other(ASCE)CF.1943-5509.0001550.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4269675
    description abstractIn this study, the construction deficiencies affecting performance of hospitals during the 2017 Sarpol-e Zahab earthquake in Iran were studied through a field survey and numerical assessment. The inadequate bracing of infill walls, façades, and false ceilings, as well as the improper infill wall materials were the nonstructural deficiencies identified through the initial field survey. Improper spacing and anchoring of the reinforcement, unanticipated frame-infill interaction, and low concrete strength were also identified as the major drawbacks of structural members. In the numerical assessment, the results of the concrete coring tests were utilized to establish an as-built nonlinear model whose response was compared with the as-designed model for evaluation purposes. For this purpose, the models were initially pushed to a target roof drift and were then subjected to nonlinear response history analyses under various levels of the Sarpol-e Zahab earthquake. The ductility demands undergone by some members of the deficient as-built model were shown to surpass the counterpart values of the stronger as-designed model, while a nearly 17% reduction was observed in the maximum base shear due to the construction deficiencies.
    publisherASCE
    titleEffect of Construction Deficiencies on Seismic Performance of Hospitals during the 2017 Sarpol-e Zahab Earthquake
    typeJournal Paper
    journal volume35
    journal issue1
    journal titleJournal of Performance of Constructed Facilities
    identifier doi10.1061/(ASCE)CF.1943-5509.0001550
    journal fristpage04020140
    journal lastpage04020140-14
    page14
    treeJournal of Performance of Constructed Facilities:;2021:;Volume ( 035 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian