    Archive

    Method of Reducing Energy Consumption for Heating Frost-Susceptible Soil around Chilled Underground Pipeline

    Source: Journal of Cold Regions Engineering:;2020:;Volume ( 034 ):;issue: 003
    Author:
    E. V. Markov
    ,
    S. A. Pulnikov
    ,
    Y. S. Sysoev
    ,
    N. V. Kazakova
    DOI: 10.1061/(ASCE)CR.1943-5495.0000217
    Publisher: ASCE
    Abstract: This article is devoted to the calculation and optimization of the engineering protection of cold underground condensate pipelines using heat-tracing cable in frost-susceptible soils in Western Siberia. The method for stress–strain state calculation of a pipeline in frost-susceptible soils has been developed. The dependence of maximal stresses in the pipeline wall on the linear heat-generation rate of the heat-tracing cable in the case of a constant heating mode has been derived. The dependence shows a monotonic decrease of maximum displacement of the pipeline and stresses in the pipeline wall with an increase of the linear heat-generation rate. The influence of a startup delay of the heat-tracing cable to the stress–strain state of the pipeline has been numerically investigated. The use of heating mode with delayed startup reduces the electrical energy consumption by 35.4% for considered pipeline comparing a constant heating mode due to fast soil freezing around a pipeline at the initial stage. The effect of energy saving depends on the linear heat-generation rate of the heat-tracing cable. For the considered pipeline, heat-tracing cable with a minimum permissible linear heat-generation rate of 1 W · m−1 and 3.5 years startup delay provides maximum energy savings.
    • Download: (755.6Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Method of Reducing Energy Consumption for Heating Frost-Susceptible Soil around Chilled Underground Pipeline

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4268404
    Collections
    • Journal of Cold Regions Engineering

    Show full item record

    contributor authorE. V. Markov
    contributor authorS. A. Pulnikov
    contributor authorY. S. Sysoev
    contributor authorN. V. Kazakova
    date accessioned2022-01-30T21:32:56Z
    date available2022-01-30T21:32:56Z
    date issued9/1/2020 12:00:00 AM
    identifier other%28ASCE%29CR.1943-5495.0000217.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4268404
    description abstractThis article is devoted to the calculation and optimization of the engineering protection of cold underground condensate pipelines using heat-tracing cable in frost-susceptible soils in Western Siberia. The method for stress–strain state calculation of a pipeline in frost-susceptible soils has been developed. The dependence of maximal stresses in the pipeline wall on the linear heat-generation rate of the heat-tracing cable in the case of a constant heating mode has been derived. The dependence shows a monotonic decrease of maximum displacement of the pipeline and stresses in the pipeline wall with an increase of the linear heat-generation rate. The influence of a startup delay of the heat-tracing cable to the stress–strain state of the pipeline has been numerically investigated. The use of heating mode with delayed startup reduces the electrical energy consumption by 35.4% for considered pipeline comparing a constant heating mode due to fast soil freezing around a pipeline at the initial stage. The effect of energy saving depends on the linear heat-generation rate of the heat-tracing cable. For the considered pipeline, heat-tracing cable with a minimum permissible linear heat-generation rate of 1 W · m−1 and 3.5 years startup delay provides maximum energy savings.
    publisherASCE
    titleMethod of Reducing Energy Consumption for Heating Frost-Susceptible Soil around Chilled Underground Pipeline
    typeJournal Paper
    journal volume34
    journal issue3
    journal titleJournal of Cold Regions Engineering
    identifier doi10.1061/(ASCE)CR.1943-5495.0000217
    page7
    treeJournal of Cold Regions Engineering:;2020:;Volume ( 034 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian