Mass, Energy, and Cost Balances in Water Distribution Systems with PATs: The Trondheim Network Case StudySource: Journal of Water Resources Planning and Management:;2020:;Volume ( 146 ):;issue: 005DOI: 10.1061/(ASCE)WR.1943-5452.0001201Publisher: ASCE
Abstract: In water distribution systems, the substitution of regulating valves by pumps as turbines (PATs) is sustainable if the energy recovery balances the installation and maintenance costs, with a comparable and efficient reduction of the volume lost by leakage. Hence, the installation feasibility and regulation of a PAT require analysis of the introduced effects on the components of the energy, mass, and cost balances. In this paper these effects are explored by means of a case study, i.e., the water distribution system of Trondheim, Norway. Different hydraulic regulations of a PAT are analyzed to maximize the recovered energy, considering the daily variation of the system functioning conditions and the substitution of valves of different kinds, meaning a constant opening degree, a fixed value of pressure at a node of the system, and a control in time of the setting. A feasible solution for the Trondheim network is shown, consisting of the implementation of two twin PATs in parallel with a discontinuous functioning of one of them.
|
Show full item record
| contributor author | Marco Ferrante | |
| contributor author | Camillo Bosco | |
| contributor author | Rita Ugarelli | |
| contributor author | Lorenzo Magenta | |
| contributor author | Tomas Eidsmo | |
| date accessioned | 2022-01-30T21:14:08Z | |
| date available | 2022-01-30T21:14:08Z | |
| date issued | 5/1/2020 12:00:00 AM | |
| identifier other | %28ASCE%29WR.1943-5452.0001201.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl1/handle/yetl/4267857 | |
| description abstract | In water distribution systems, the substitution of regulating valves by pumps as turbines (PATs) is sustainable if the energy recovery balances the installation and maintenance costs, with a comparable and efficient reduction of the volume lost by leakage. Hence, the installation feasibility and regulation of a PAT require analysis of the introduced effects on the components of the energy, mass, and cost balances. In this paper these effects are explored by means of a case study, i.e., the water distribution system of Trondheim, Norway. Different hydraulic regulations of a PAT are analyzed to maximize the recovered energy, considering the daily variation of the system functioning conditions and the substitution of valves of different kinds, meaning a constant opening degree, a fixed value of pressure at a node of the system, and a control in time of the setting. A feasible solution for the Trondheim network is shown, consisting of the implementation of two twin PATs in parallel with a discontinuous functioning of one of them. | |
| publisher | ASCE | |
| title | Mass, Energy, and Cost Balances in Water Distribution Systems with PATs: The Trondheim Network Case Study | |
| type | Journal Paper | |
| journal volume | 146 | |
| journal issue | 5 | |
| journal title | Journal of Water Resources Planning and Management | |
| identifier doi | 10.1061/(ASCE)WR.1943-5452.0001201 | |
| page | 8 | |
| tree | Journal of Water Resources Planning and Management:;2020:;Volume ( 146 ):;issue: 005 | |
| contenttype | Fulltext |