| contributor author | Chenxi Lu | |
| contributor author | James St. Onge | |
| contributor author | Amir Fam | |
| date accessioned | 2022-01-30T19:58:11Z | |
| date available | 2022-01-30T19:58:11Z | |
| date issued | 2020 | |
| identifier other | %28ASCE%29CC.1943-5614.0000990.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl1/handle/yetl/4266297 | |
| description abstract | Concrete-filled fiber-reinforced polymer (FRP) tubes (CFFTs) have been studied extensively, but a lingering question remains regarding the vulnerability of the exposed tube to accidental damage or vandalism. In this paper, the effect of damage induced in the tubes on the flexural strength of CFFTs is studied. A total of 18 specimens with tubes having nearly orthogonal fiber arrangements were tested in four-point bending, including one undamaged control specimen to establish its full nominal strength (Mno). A total of 11 specimens with artificially induced damage in the form of through-thickness cuts on the tension side, and six with cuts on the compression side at midspan were also tested. Longitudinal, circumferential, and square cuts were introduced. Cut length and proximity to neutral axis were varied. It is shown that the most critical cut is the circumferential one on extreme tension. A sharp decline occurred initially in the nominal residual strength ratio (Mn/Mno), from 1.0 to 0.55 at a cut length-to-perimeter ratio of 0.02πD, followed by a much less steep trend up to Mn/Mno of 0.25 at a 0.2πD cut. As the location of a 0.03πD circumferential cut shifted from extreme tension to an 80° from the bottom, Mn/Mno increased from 0.52 to 1.0. A longitudinal cut of 0.1πD on the tension side resulted in Mn/Mno of 0.69 as opposed to 0.38 for the circumferential cut. Compression side longitudinal and circumferential cuts were less critical with Mn/Mno of 0.8 to 0.9. For practical design, a case study based on ultimate static strength showed that the CFFT can tolerate a circumferential tension cut of up to 0.29πD before it has to be taken out of service. | |
| publisher | ASCE | |
| title | Damage Threshold of Near-Cross-Ply Tubes Used in Concrete-Filled FRP Tubes Loaded in Flexure | |
| type | Journal Paper | |
| journal volume | 24 | |
| journal issue | 2 | |
| journal title | Journal of Composites for Construction | |
| identifier doi | 10.1061/(ASCE)CC.1943-5614.0000990 | |
| page | 04019063 | |
| tree | Journal of Composites for Construction:;2020:;Volume ( 024 ):;issue: 002 | |
| contenttype | Fulltext | |