    Load Testing and Rating of Cast-in-Place Concrete Box Culverts

    Source: Journal of Performance of Constructed Facilities:;2020:;Volume ( 034 ):;issue: 002
    Author:
    Tuna Ulger
    ,
    Ayman M. Okeil
    ,
    Ahmed Elshoura
    DOI: 10.1061/(ASCE)CF.1943-5509.0001401
    Publisher: ASCE
    Abstract: One of the largest items in the bridge inventory for many states is culverts, and cast-in-place reinforced concrete box culverts constitute a sizeable portion of the overall culvert inventory. In Louisiana, most of these culverts were constructed using old standard details. Following current load rating procedures for these culverts often yields unacceptable load rating factors, even though their performance is acceptable with no signs of distress. The discrepancy between calculated load rating and observed performance of the culverts is investigated for eight selected culverts by field live load testing and finite element modeling. Each culvert was instrumented using a 48-sensor structural health monitoring system before a loaded truck was driven on the culvert along three different load paths to collect field data. Three-dimensional (3D) finite element (FE) models were calibrated using the recorded field data, and an HL-93 design truck and 10 legal trucks such as Type 3-3 were used to load the calibrated FE models to obtain culvert specific load rating factors. Acceptable rating factors were obtained for all eight culverts. The rating methodology, rating factors, and recommendations for rating culverts are presented in this paper.
    • Download: (1.882Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Load Testing and Rating of Cast-in-Place Concrete Box Culverts

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4265040
    Collections
    • Journal of Performance of Constructed Facilities

    Show full item record

    contributor authorTuna Ulger
    contributor authorAyman M. Okeil
    contributor authorAhmed Elshoura
    date accessioned2022-01-30T19:18:38Z
    date available2022-01-30T19:18:38Z
    date issued2020
    identifier other%28ASCE%29CF.1943-5509.0001401.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4265040
    description abstractOne of the largest items in the bridge inventory for many states is culverts, and cast-in-place reinforced concrete box culverts constitute a sizeable portion of the overall culvert inventory. In Louisiana, most of these culverts were constructed using old standard details. Following current load rating procedures for these culverts often yields unacceptable load rating factors, even though their performance is acceptable with no signs of distress. The discrepancy between calculated load rating and observed performance of the culverts is investigated for eight selected culverts by field live load testing and finite element modeling. Each culvert was instrumented using a 48-sensor structural health monitoring system before a loaded truck was driven on the culvert along three different load paths to collect field data. Three-dimensional (3D) finite element (FE) models were calibrated using the recorded field data, and an HL-93 design truck and 10 legal trucks such as Type 3-3 were used to load the calibrated FE models to obtain culvert specific load rating factors. Acceptable rating factors were obtained for all eight culverts. The rating methodology, rating factors, and recommendations for rating culverts are presented in this paper.
    publisherASCE
    titleLoad Testing and Rating of Cast-in-Place Concrete Box Culverts
    typeJournal Paper
    journal volume34
    journal issue2
    journal titleJournal of Performance of Constructed Facilities
    identifier doi10.1061/(ASCE)CF.1943-5509.0001401
    page04020008
    treeJournal of Performance of Constructed Facilities:;2020:;Volume ( 034 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian