    Topological Placement of Quality Sensors in Water-Distribution Networks without the Recourse to Hydraulic Modeling

    Source: Journal of Water Resources Planning and Management:;2020:;Volume ( 146 ):;issue: 006
    Author:
    C. Giudicianni
    ,
    M. Herrera
    ,
    A. Di Nardo
    ,
    R. Greco
    ,
    E. Creaco
    ,
    A. Scala
    DOI: 10.1061/(ASCE)WR.1943-5452.0001210
    Publisher: ASCE
    Abstract: The detection of contaminant intrusion into a water-distribution network (WDN) is a difficult issue due to uncertainty related to the type of injected contaminant, source location, and intrusion time. The placement of water quality sensors has received increasing interest in the last years, and it still represents an open problem and a great challenge for researchers and utilities. Efficient numerical techniques are needed to support any contamination warning system (CWS) design. These require a well-calibrated hydraulic model of the WDN and a great deal of information, both of which are often unavailable to water utilities. In addition, as the size of the WDN increases, the choice of effective sensor placement becomes a computationally intractable problem. This paper introduces a methodology to support water utilities in the design of an effective CWS without any use of hydraulic information, but just exploiting the knowledge of the topology of the WDN. To ensure a complete coverage of the network, the method relies on a priori clustering of the WDN and on the installation of quality sensors at the most central nodes of each cluster, selected according to different topological centrality metrics. The procedure is tested on a benchmark network and on a real WDN serving a town close to Naples, Italy. The solutions obtained with topological criteria are effective in terms of detection time, detection likelihood, redundancy, and population exposed through ingestion.
    • Download: (735.2Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Topological Placement of Quality Sensors in Water-Distribution Networks without the Recourse to Hydraulic Modeling

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4264722
    Collections
    • Journal of Water Resources Planning and Management

    Show full item record

    contributor authorC. Giudicianni
    contributor authorM. Herrera
    contributor authorA. Di Nardo
    contributor authorR. Greco
    contributor authorE. Creaco
    contributor authorA. Scala
    date accessioned2022-01-30T19:08:15Z
    date available2022-01-30T19:08:15Z
    date issued2020
    identifier other%28ASCE%29WR.1943-5452.0001210.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4264722
    description abstractThe detection of contaminant intrusion into a water-distribution network (WDN) is a difficult issue due to uncertainty related to the type of injected contaminant, source location, and intrusion time. The placement of water quality sensors has received increasing interest in the last years, and it still represents an open problem and a great challenge for researchers and utilities. Efficient numerical techniques are needed to support any contamination warning system (CWS) design. These require a well-calibrated hydraulic model of the WDN and a great deal of information, both of which are often unavailable to water utilities. In addition, as the size of the WDN increases, the choice of effective sensor placement becomes a computationally intractable problem. This paper introduces a methodology to support water utilities in the design of an effective CWS without any use of hydraulic information, but just exploiting the knowledge of the topology of the WDN. To ensure a complete coverage of the network, the method relies on a priori clustering of the WDN and on the installation of quality sensors at the most central nodes of each cluster, selected according to different topological centrality metrics. The procedure is tested on a benchmark network and on a real WDN serving a town close to Naples, Italy. The solutions obtained with topological criteria are effective in terms of detection time, detection likelihood, redundancy, and population exposed through ingestion.
    publisherASCE
    titleTopological Placement of Quality Sensors in Water-Distribution Networks without the Recourse to Hydraulic Modeling
    typeJournal Paper
    journal volume146
    journal issue6
    journal titleJournal of Water Resources Planning and Management
    identifier doi10.1061/(ASCE)WR.1943-5452.0001210
    page04020030
    treeJournal of Water Resources Planning and Management:;2020:;Volume ( 146 ):;issue: 006
    contenttypeFulltext