    The Influence of Cylindrical Spray Chamber Geometry on the Evolution of High Pressure Diesel Sprays

    Source: Journal of Fluids Engineering:;2019:;volume( 141 ):;issue: 010::page 101102
    Author:
    Nguyen, Dung
    ,
    Honnery, Damon
    DOI: 10.1115/1.4043234
    Publisher: American Society of Mechanical Engineers (ASME)
    Abstract: While much is known on the effect of combustion chamber geometry on spray evolution in engines, less is known about its role in laboratory combustion chambers. This paper reports on a study, which investigates the effect of internal chamber geometry on the penetration and spreading angle of common rail nonreacting diesel sprays at room temperature conditions in a cylindrical constant volume chamber. This chamber has dimensions similar to those used in the literature. Spray chamber geometry was modified to yield three different chamber height-to-diameter ratios and two different nozzle stand-off distances. Sprays from three nozzles, two single-hole nozzles with different diameter and one twin-hole nozzle (THN), were examined for two injection pressures of 100 MPa and 150 MPa into two chamber pressures of 0.1 MPa and 5 MPa. To characterize the spray structure, a volume illumination method was used to study the spray tip penetration/speed and spread angle. For both injection pressures used with chamber pressure of 5 MPa, little sensitivity to vessel geometry was found in penetration distance and tip speed for variation in height to diameter ratio from 0.6 to 2.6 and variation in nozzle stand-off distance from 2 mm to 54 mm. For atmospheric chamber pressure, sensitivity to chamber geometry was evident and found to vary with nozzle type. Spread angle was found more largely affected by the calculation method and very sensitive to the image intensity threshold value for the cases investigated.
    • Download: (4.379Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      The Influence of Cylindrical Spray Chamber Geometry on the Evolution of High Pressure Diesel Sprays

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4259008
    Collections
    • Journal of Fluids Engineering

    Show full item record

    contributor authorNguyen, Dung
    contributor authorHonnery, Damon
    date accessioned2019-09-18T09:06:48Z
    date available2019-09-18T09:06:48Z
    date copyright4/15/2019 12:00:00 AM
    date issued2019
    identifier issn0098-2202
    identifier otherfe_141_10_101102
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4259008
    description abstractWhile much is known on the effect of combustion chamber geometry on spray evolution in engines, less is known about its role in laboratory combustion chambers. This paper reports on a study, which investigates the effect of internal chamber geometry on the penetration and spreading angle of common rail nonreacting diesel sprays at room temperature conditions in a cylindrical constant volume chamber. This chamber has dimensions similar to those used in the literature. Spray chamber geometry was modified to yield three different chamber height-to-diameter ratios and two different nozzle stand-off distances. Sprays from three nozzles, two single-hole nozzles with different diameter and one twin-hole nozzle (THN), were examined for two injection pressures of 100 MPa and 150 MPa into two chamber pressures of 0.1 MPa and 5 MPa. To characterize the spray structure, a volume illumination method was used to study the spray tip penetration/speed and spread angle. For both injection pressures used with chamber pressure of 5 MPa, little sensitivity to vessel geometry was found in penetration distance and tip speed for variation in height to diameter ratio from 0.6 to 2.6 and variation in nozzle stand-off distance from 2 mm to 54 mm. For atmospheric chamber pressure, sensitivity to chamber geometry was evident and found to vary with nozzle type. Spread angle was found more largely affected by the calculation method and very sensitive to the image intensity threshold value for the cases investigated.
    publisherAmerican Society of Mechanical Engineers (ASME)
    titleThe Influence of Cylindrical Spray Chamber Geometry on the Evolution of High Pressure Diesel Sprays
    typeJournal Paper
    journal volume141
    journal issue10
    journal titleJournal of Fluids Engineering
    identifier doi10.1115/1.4043234
    journal fristpage101102
    journal lastpage101102-11
    treeJournal of Fluids Engineering:;2019:;volume( 141 ):;issue: 010
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian