    Glasses for Nuclear Waste Immobilization. Effect of Lutetium Addition on Yttrium Aluminosilicate Glass Crystallization Kinetics

    Source: Journal of Nuclear Engineering and Radiation Science:;2019:;volume( 005 ):;issue: 002::page 20907
    Author:
    Lago, D. C.
    ,
    Bortot, M. B.
    ,
    Prado, M. O.
    DOI: 10.1115/1.4042497
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Glasses have emerged as alternative materials that can be used for long-term treatment and management of radioactive waste. Specifically, glasses can be used as a matrix to immobilize the radioactive material. Within the glass industry, silicate glasses are the most widely used due to their properties and to the large knowledge existent about them. Alkaline free silicate glasses are particularly corrosion resistant. Due to the latter, rare earth aluminosilicate glasses are good candidates for actinides immobilization, especially, yttrium aluminosilicate (YAS) glasses. The crystallization kinetics of YAS glasses on heating has been already studied, and this work is focused on the effect of lutetium addition on the YAS glass crystallization kinetics. The presence of a small amount of lutetium in a YAS glass decreases the surface density of nucleation sites (Ns) by about 1 order of magnitude and significantly decreases the crystal growth rate (U). In this work, it was observed that lutetium additions on the order of 0.2 (wt %) to a YAS glass dramatically decreased Ns, for example, at 1000 °C from 1011 to 109 nuclei/m2. Additionally, U for yttrium disilicate phase decreased from (8.21 ± 0.28) μm/h to (0.54 ± 0.04) μm/h at the same temperature.
    • Download: (1.998Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Glasses for Nuclear Waste Immobilization. Effect of Lutetium Addition on Yttrium Aluminosilicate Glass Crystallization Kinetics

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4257657
    Collections
    • Journal of Nuclear Engineering and Radiation Science

    Show full item record

    contributor authorLago, D. C.
    contributor authorBortot, M. B.
    contributor authorPrado, M. O.
    date accessioned2019-06-08T09:29:02Z
    date available2019-06-08T09:29:02Z
    date copyright3/15/2019 12:00:00 AM
    date issued2019
    identifier issn2332-8983
    identifier otherners_005_02_020907.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4257657
    description abstractGlasses have emerged as alternative materials that can be used for long-term treatment and management of radioactive waste. Specifically, glasses can be used as a matrix to immobilize the radioactive material. Within the glass industry, silicate glasses are the most widely used due to their properties and to the large knowledge existent about them. Alkaline free silicate glasses are particularly corrosion resistant. Due to the latter, rare earth aluminosilicate glasses are good candidates for actinides immobilization, especially, yttrium aluminosilicate (YAS) glasses. The crystallization kinetics of YAS glasses on heating has been already studied, and this work is focused on the effect of lutetium addition on the YAS glass crystallization kinetics. The presence of a small amount of lutetium in a YAS glass decreases the surface density of nucleation sites (Ns) by about 1 order of magnitude and significantly decreases the crystal growth rate (U). In this work, it was observed that lutetium additions on the order of 0.2 (wt %) to a YAS glass dramatically decreased Ns, for example, at 1000 °C from 1011 to 109 nuclei/m2. Additionally, U for yttrium disilicate phase decreased from (8.21 ± 0.28) μm/h to (0.54 ± 0.04) μm/h at the same temperature.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleGlasses for Nuclear Waste Immobilization. Effect of Lutetium Addition on Yttrium Aluminosilicate Glass Crystallization Kinetics
    typeJournal Paper
    journal volume5
    journal issue2
    journal titleJournal of Nuclear Engineering and Radiation Science
    identifier doi10.1115/1.4042497
    journal fristpage20907
    journal lastpage020907-6
    treeJournal of Nuclear Engineering and Radiation Science:;2019:;volume( 005 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian