    Improvement in Film Cooling Effectiveness Using Single and Double Rows of Holes With Adverse Compound Angle Orientations

    Source: Journal of Thermal Science and Engineering Applications:;2019:;volume( 011 ):;issue: 002::page 21014
    Author:
    Kannan, E.
    ,
    Sivamani, Seralathan
    ,
    Roychowdhury, D. G.
    ,
    Micha Premkumar, T.
    ,
    Hariram, V.
    DOI: 10.1115/1.4041937
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Three-dimensional Reynolds-averaged Navier–Stokes equations with shear stress transport turbulence model are used to analyze the film cooling effectiveness on a flat plate having single row of film hole involving cylindrical hole (CH) and laidback hole (LBH). The CH and LBH are inclined at 35 deg to the surface with a compound angle (β) orientation ranging from favorable to adverse inclination (i.e., β = 0–180 deg) and examined at high and low blowing ratios (M = 1.25 and 0.60). CH with an adverse compound angle of 135 deg gives the highest area-averaged film cooling effectiveness in comparison with LBH configuration. Also, CH β = 135 deg film hole shows a higher lateral coolant spread. Later, double jet film cooling (DJFC) concept is studied for this CH. In all the cases, the first hole compound angle is fixed as 135 deg, and the second hole angle is varied from 135 deg to 315 deg. At high blowing ratio, the dual jet cylindrical hole (DJCH) with β = 135 deg, 315 deg gives a higher area-averaged film cooling effectiveness by around 66.50% compared to baseline CH β = 0 deg. On comparing all CH, LBH, and DJCH cases, the highest area-averaged film cooling effectiveness is obtained by CH configuration with β = 135 deg. Hence, the CH with its adverse compound angle (β = 135 deg) orientation could be an appropriate film cooling configuration for gas turbine blade cooling.
    • Download: (6.732Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Improvement in Film Cooling Effectiveness Using Single and Double Rows of Holes With Adverse Compound Angle Orientations

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4256552
    Collections
    • Journal of Thermal Science and Engineering Applications

    Show full item record

    contributor authorKannan, E.
    contributor authorSivamani, Seralathan
    contributor authorRoychowdhury, D. G.
    contributor authorMicha Premkumar, T.
    contributor authorHariram, V.
    date accessioned2019-03-17T11:02:12Z
    date available2019-03-17T11:02:12Z
    date copyright12/6/2018 12:00:00 AM
    date issued2019
    identifier issn1948-5085
    identifier othertsea_011_02_021014.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4256552
    description abstractThree-dimensional Reynolds-averaged Navier–Stokes equations with shear stress transport turbulence model are used to analyze the film cooling effectiveness on a flat plate having single row of film hole involving cylindrical hole (CH) and laidback hole (LBH). The CH and LBH are inclined at 35 deg to the surface with a compound angle (β) orientation ranging from favorable to adverse inclination (i.e., β = 0–180 deg) and examined at high and low blowing ratios (M = 1.25 and 0.60). CH with an adverse compound angle of 135 deg gives the highest area-averaged film cooling effectiveness in comparison with LBH configuration. Also, CH β = 135 deg film hole shows a higher lateral coolant spread. Later, double jet film cooling (DJFC) concept is studied for this CH. In all the cases, the first hole compound angle is fixed as 135 deg, and the second hole angle is varied from 135 deg to 315 deg. At high blowing ratio, the dual jet cylindrical hole (DJCH) with β = 135 deg, 315 deg gives a higher area-averaged film cooling effectiveness by around 66.50% compared to baseline CH β = 0 deg. On comparing all CH, LBH, and DJCH cases, the highest area-averaged film cooling effectiveness is obtained by CH configuration with β = 135 deg. Hence, the CH with its adverse compound angle (β = 135 deg) orientation could be an appropriate film cooling configuration for gas turbine blade cooling.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleImprovement in Film Cooling Effectiveness Using Single and Double Rows of Holes With Adverse Compound Angle Orientations
    typeJournal Paper
    journal volume11
    journal issue2
    journal titleJournal of Thermal Science and Engineering Applications
    identifier doi10.1115/1.4041937
    journal fristpage21014
    journal lastpage021014-19
    treeJournal of Thermal Science and Engineering Applications:;2019:;volume( 011 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian