YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • Journal of Engineering for Gas Turbines and Power
    • View Item
    •   YE&T Library
    • ASME
    • Journal of Engineering for Gas Turbines and Power
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Gas Turbine Fouling: A Comparison Among 100 Heavy-Duty Frames

    Source: Journal of Engineering for Gas Turbines and Power:;2019:;volume( 141 ):;issue: 003::page 32401
    Author:
    Aldi, Nicola
    ,
    Casari, Nicola
    ,
    Morini, Mirko
    ,
    Pinelli, Michele
    ,
    Spina, Pier Ruggero
    ,
    Suman, Alessio
    DOI: 10.1115/1.4041249
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Over recent decades, the variability and high costs of the traditional gas turbine fuels (e.g., natural gas) have pushed operators to consider low-grade fuels for running heavy-duty frames. Synfuels, obtained from coal, petroleum, or biomass gasification, could represent valid alternatives in this sense. Although these alternatives match the reduction of costs and, in the case of biomass sources, would potentially provide a CO2 emission benefit (reduction of the CO2 capture and sequestration costs), these low-grade fuels have a higher content of contaminants. Synfuels are filtered before the combustor stage, but the contaminants are not removed completely. This fact leads to a considerable amount of deposition on the nozzle vanes due to the high temperature value. In addition to this, the continuous demand for increasing gas turbine efficiency determines a higher combustor outlet temperature. Current advanced gas turbine engines operate at a turbine inlet temperature (TIT) of (1400–1500) °C, which is high enough to melt a high proportion of the contaminants introduced by low-grade fuels. Particle deposition can increase surface roughness, modify the airfoil shape, and clog the coolant passages. At the same time, land-based power units experience compressor fouling, due to the air contaminants able to pass through the filtration barriers. Hot sections and compressor fouling work together to determine performance degradation. This paper proposes an analysis of the contaminant deposition on hot gas turbine sections based on machine nameplate data. Hot section and compressor fouling are estimated using a fouling susceptibility criterion. The combination of gas turbine net power, efficiency, and TIT with different types of synfuel contaminants highlights how each gas turbine is subjected to particle deposition. The simulation of particle deposition on 100 gas turbines ranging from 1.2 MW to 420 MW was conducted following the fouling susceptibility criterion. Using a simplified particle deposition calculation based on TIT and contaminant viscosity estimation, the analysis shows how the correlation between type of contaminant and gas turbine performance plays a key role. The results allow the choice of the best heavy-duty frame as a function of the fuel. Low-efficiency frames (characterized by lower values of TIT) show the best compromise in order to reduce the effects of particle deposition in the presence of high-temperature melting contaminants. A high-efficiency frame is suitable when the contaminants are characterized by a low-melting point thanks to their lower fuel consumption.
    • Download: (3.005Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Gas Turbine Fouling: A Comparison Among 100 Heavy-Duty Frames

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4256046
    Collections
    • Journal of Engineering for Gas Turbines and Power

    Show full item record

    contributor authorAldi, Nicola
    contributor authorCasari, Nicola
    contributor authorMorini, Mirko
    contributor authorPinelli, Michele
    contributor authorSpina, Pier Ruggero
    contributor authorSuman, Alessio
    date accessioned2019-03-17T10:16:57Z
    date available2019-03-17T10:16:57Z
    date copyright10/4/2018 12:00:00 AM
    date issued2019
    identifier issn0742-4795
    identifier othergtp_141_03_032401.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4256046
    description abstractOver recent decades, the variability and high costs of the traditional gas turbine fuels (e.g., natural gas) have pushed operators to consider low-grade fuels for running heavy-duty frames. Synfuels, obtained from coal, petroleum, or biomass gasification, could represent valid alternatives in this sense. Although these alternatives match the reduction of costs and, in the case of biomass sources, would potentially provide a CO2 emission benefit (reduction of the CO2 capture and sequestration costs), these low-grade fuels have a higher content of contaminants. Synfuels are filtered before the combustor stage, but the contaminants are not removed completely. This fact leads to a considerable amount of deposition on the nozzle vanes due to the high temperature value. In addition to this, the continuous demand for increasing gas turbine efficiency determines a higher combustor outlet temperature. Current advanced gas turbine engines operate at a turbine inlet temperature (TIT) of (1400–1500) °C, which is high enough to melt a high proportion of the contaminants introduced by low-grade fuels. Particle deposition can increase surface roughness, modify the airfoil shape, and clog the coolant passages. At the same time, land-based power units experience compressor fouling, due to the air contaminants able to pass through the filtration barriers. Hot sections and compressor fouling work together to determine performance degradation. This paper proposes an analysis of the contaminant deposition on hot gas turbine sections based on machine nameplate data. Hot section and compressor fouling are estimated using a fouling susceptibility criterion. The combination of gas turbine net power, efficiency, and TIT with different types of synfuel contaminants highlights how each gas turbine is subjected to particle deposition. The simulation of particle deposition on 100 gas turbines ranging from 1.2 MW to 420 MW was conducted following the fouling susceptibility criterion. Using a simplified particle deposition calculation based on TIT and contaminant viscosity estimation, the analysis shows how the correlation between type of contaminant and gas turbine performance plays a key role. The results allow the choice of the best heavy-duty frame as a function of the fuel. Low-efficiency frames (characterized by lower values of TIT) show the best compromise in order to reduce the effects of particle deposition in the presence of high-temperature melting contaminants. A high-efficiency frame is suitable when the contaminants are characterized by a low-melting point thanks to their lower fuel consumption.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleGas Turbine Fouling: A Comparison Among 100 Heavy-Duty Frames
    typeJournal Paper
    journal volume141
    journal issue3
    journal titleJournal of Engineering for Gas Turbines and Power
    identifier doi10.1115/1.4041249
    journal fristpage32401
    journal lastpage032401-12
    treeJournal of Engineering for Gas Turbines and Power:;2019:;volume( 141 ):;issue: 003
    contenttypeFulltext