    Archive

    Development and Validation of SAS4A Code and Its Application to Analyses on Severe Flow Blockage Accidents in a Sodium-Cooled Fast Reactor

    Source: Journal of Nuclear Engineering and Radiation Science:;2019:;volume( 005 ):;issue: 001::page 11001
    Author:
    Fukano, Yoshitaka
    DOI: 10.1115/1.4040649
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Local subassembly faults (LFs) have been considered to be of greater importance in safety evaluation in sodium-cooled fast reactors (SFRs) because fuel elements were generally densely arranged in the subassemblies (SAs) in this type of reactors, and because power densities were higher compared with those in light water reactors. A hypothetical total instantaneous flow blockage (HTIB) at the coolant inlet of an SA gives most severe consequences among a variety of LFs. Although an evaluation on the consequences of HTIB using SAS4A code was performed in the past study, SAS4A code was further developed by implementing analytical model of power control system in this study. An evaluation on the consequences of HTIB in an SFR by this developed SAS4A code was also performed in this study. It was clarified by the analyses considering power control system that the reactor would be safely shut down by the reactor protection system triggered by either of 116% over power or delayed neutron detector (DND) trip signals. Therefore, the conclusion in the past study that the consequences of HTIB would be much less severe than that of unprotected-loss-of-flow (ULOF) was strongly supported by this study. Furthermore, SAS4A code was newly validated using four in-pile experiments which simulated HTIB events. The validity of SAS4A application to safety evaluation on the consequence of HTIB was further enhanced in this study. Thus, the methodology of HTIB evaluation was established in this study together with the past study and is applicable to HTIB evaluations in other SFRs.
    • Download: (6.269Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Development and Validation of SAS4A Code and Its Application to Analyses on Severe Flow Blockage Accidents in a Sodium-Cooled Fast Reactor

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4255608
    Collections
    • Journal of Nuclear Engineering and Radiation Science

    Show full item record

    contributor authorFukano, Yoshitaka
    date accessioned2019-03-17T09:40:30Z
    date available2019-03-17T09:40:30Z
    date copyright1/24/2019 12:00:00 AM
    date issued2019
    identifier issn2332-8983
    identifier otherners_005_01_011001.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4255608
    description abstractLocal subassembly faults (LFs) have been considered to be of greater importance in safety evaluation in sodium-cooled fast reactors (SFRs) because fuel elements were generally densely arranged in the subassemblies (SAs) in this type of reactors, and because power densities were higher compared with those in light water reactors. A hypothetical total instantaneous flow blockage (HTIB) at the coolant inlet of an SA gives most severe consequences among a variety of LFs. Although an evaluation on the consequences of HTIB using SAS4A code was performed in the past study, SAS4A code was further developed by implementing analytical model of power control system in this study. An evaluation on the consequences of HTIB in an SFR by this developed SAS4A code was also performed in this study. It was clarified by the analyses considering power control system that the reactor would be safely shut down by the reactor protection system triggered by either of 116% over power or delayed neutron detector (DND) trip signals. Therefore, the conclusion in the past study that the consequences of HTIB would be much less severe than that of unprotected-loss-of-flow (ULOF) was strongly supported by this study. Furthermore, SAS4A code was newly validated using four in-pile experiments which simulated HTIB events. The validity of SAS4A application to safety evaluation on the consequence of HTIB was further enhanced in this study. Thus, the methodology of HTIB evaluation was established in this study together with the past study and is applicable to HTIB evaluations in other SFRs.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleDevelopment and Validation of SAS4A Code and Its Application to Analyses on Severe Flow Blockage Accidents in a Sodium-Cooled Fast Reactor
    typeJournal Paper
    journal volume5
    journal issue1
    journal titleJournal of Nuclear Engineering and Radiation Science
    identifier doi10.1115/1.4040649
    journal fristpage11001
    journal lastpage011001-13
    treeJournal of Nuclear Engineering and Radiation Science:;2019:;volume( 005 ):;issue: 001
    contenttypeFulltext