    Valve Operability During a Fire

    Source: Journal of Offshore Mechanics and Arctic Engineering:;2019:;volume( 141 ):;issue: 004::page 44001
    Author:
    Sotoodeh, Karan
    DOI: 10.1115/1.4042073
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Fire and explosion are a major cause of concern for refinery, gas processing, petrochemical, and gas installations. The safest way to deal with a fire is to prevent it. However, fire prevention strategies are not always successful, and fires can happen. Therefore, valves should be designed and tested to be fire-safe. This paper reviews valve design features that can help prevent fires, including secondary sealing between the ball and body in case of losing a soft seat, a graphite fire-safe ring design for stem and seat sealing, antistatic devices, and antistatic tests to ensure that the valve is fire-safe. In addition to design considerations, a fire-safe design should be validated through tests defined in standards such as API 607, API RP 6FA, and ISO 10497. The API RP 6FA tests reviewed in this paper include seven tests that check the operability of the valve from closed to open position. A case study was done to prove the operability of a fail close 38″ pipeline ball valve on an oil export pipeline in case of fire during the first 20 s from the open to the closed position. Thermal analysis on the body of the valve proved that there was no thermal expansion inside the valve after 150 s of fire. Additionally, the maximum radial displacement on the valve body after 150 s of fire was 0.34 mm which is negligible. Thus, the valve thermal expansion did not disturb the operation of the valve after 20 s.
    • Download: (1.327Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Valve Operability During a Fire

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4255495
    Collections
    • Journal of Offshore Mechanics and Arctic Engineering

    Show full item record

    contributor authorSotoodeh, Karan
    date accessioned2019-03-17T09:27:09Z
    date available2019-03-17T09:27:09Z
    date copyright1/17/2019 12:00:00 AM
    date issued2019
    identifier issn0892-7219
    identifier otheromae_141_04_044001.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4255495
    description abstractFire and explosion are a major cause of concern for refinery, gas processing, petrochemical, and gas installations. The safest way to deal with a fire is to prevent it. However, fire prevention strategies are not always successful, and fires can happen. Therefore, valves should be designed and tested to be fire-safe. This paper reviews valve design features that can help prevent fires, including secondary sealing between the ball and body in case of losing a soft seat, a graphite fire-safe ring design for stem and seat sealing, antistatic devices, and antistatic tests to ensure that the valve is fire-safe. In addition to design considerations, a fire-safe design should be validated through tests defined in standards such as API 607, API RP 6FA, and ISO 10497. The API RP 6FA tests reviewed in this paper include seven tests that check the operability of the valve from closed to open position. A case study was done to prove the operability of a fail close 38″ pipeline ball valve on an oil export pipeline in case of fire during the first 20 s from the open to the closed position. Thermal analysis on the body of the valve proved that there was no thermal expansion inside the valve after 150 s of fire. Additionally, the maximum radial displacement on the valve body after 150 s of fire was 0.34 mm which is negligible. Thus, the valve thermal expansion did not disturb the operation of the valve after 20 s.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleValve Operability During a Fire
    typeJournal Paper
    journal volume141
    journal issue4
    journal titleJournal of Offshore Mechanics and Arctic Engineering
    identifier doi10.1115/1.4042073
    journal fristpage44001
    journal lastpage044001-4
    treeJournal of Offshore Mechanics and Arctic Engineering:;2019:;volume( 141 ):;issue: 004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian