YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASCE
    • Journal of Engineering Mechanics
    • View Item
    •   YE&T Library
    • ASCE
    • Journal of Engineering Mechanics
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Tuned Mass Damper and Base Isolation: A Unitary Approach for the Seismic Protection of Conventional Frame Structures

    Source: Journal of Engineering Mechanics:;2019:;Volume ( 145 ):;issue: 004
    Author:
    Cristiano Fabrizio; Andrea M. de Leo; Angelo Di Egidio
    DOI: 10.1061/(ASCE)EM.1943-7889.0001581
    Publisher: American Society of Civil Engineers
    Abstract: Taking inspiration from the basic two-degree-of-freedom (2-DOF) models usually adopted to study base isolation (BI) and tuned mass damper (TMD), a unique main archetype 2-DOF model is here introduced to describe the behavior of general multi-degree-of-freedom (MDOF) frame systems, in which a stiffness discontinuity (disconnection), such as the one that can be identified in BI or TMD, may be inserted. With the aim to evaluate the dynamic enhancement following from such a discontinuity for the two masses of the model, two reference schemes (TMD scheme and BI scheme) are introduced and two particular mean gain parameters are associated with them. These represent the main subject of the parametric analyses presented in this work, based on variable mass and stiffness ratios. These analyses are carried out considering groups of earthquake records collected on the basis of a specific criterion (spectrum compatibility). The results of the parametric analyses are arranged by means of mean gain maps and surfaces that can be directly related to a reference response spectrum. The mean gain maps provide a description of the dynamic performance of the archetype model. In order to extend the results obtained for the archetype models to general MDOF frame systems, a specific equivalence procedure is then introduced. Using such an approach, it is possible to define values of mass and stiffness ratio for a general MDOF systems, and then to use the maps to design the characteristics of the disconnection. The results expressed by the mean gain maps have been confirmed by several simulations carried out with reference to a 6-story shear-type frame, thus showing some practical implications of the research.
    • Download: (5.305Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Tuned Mass Damper and Base Isolation: A Unitary Approach for the Seismic Protection of Conventional Frame Structures

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4254864
    Collections
    • Journal of Engineering Mechanics

    Show full item record

    contributor authorCristiano Fabrizio; Andrea M. de Leo; Angelo Di Egidio
    date accessioned2019-03-10T12:05:57Z
    date available2019-03-10T12:05:57Z
    date issued2019
    identifier other%28ASCE%29EM.1943-7889.0001581.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4254864
    description abstractTaking inspiration from the basic two-degree-of-freedom (2-DOF) models usually adopted to study base isolation (BI) and tuned mass damper (TMD), a unique main archetype 2-DOF model is here introduced to describe the behavior of general multi-degree-of-freedom (MDOF) frame systems, in which a stiffness discontinuity (disconnection), such as the one that can be identified in BI or TMD, may be inserted. With the aim to evaluate the dynamic enhancement following from such a discontinuity for the two masses of the model, two reference schemes (TMD scheme and BI scheme) are introduced and two particular mean gain parameters are associated with them. These represent the main subject of the parametric analyses presented in this work, based on variable mass and stiffness ratios. These analyses are carried out considering groups of earthquake records collected on the basis of a specific criterion (spectrum compatibility). The results of the parametric analyses are arranged by means of mean gain maps and surfaces that can be directly related to a reference response spectrum. The mean gain maps provide a description of the dynamic performance of the archetype model. In order to extend the results obtained for the archetype models to general MDOF frame systems, a specific equivalence procedure is then introduced. Using such an approach, it is possible to define values of mass and stiffness ratio for a general MDOF systems, and then to use the maps to design the characteristics of the disconnection. The results expressed by the mean gain maps have been confirmed by several simulations carried out with reference to a 6-story shear-type frame, thus showing some practical implications of the research.
    publisherAmerican Society of Civil Engineers
    titleTuned Mass Damper and Base Isolation: A Unitary Approach for the Seismic Protection of Conventional Frame Structures
    typeJournal Paper
    journal volume145
    journal issue4
    journal titleJournal of Engineering Mechanics
    identifier doi10.1061/(ASCE)EM.1943-7889.0001581
    page04019011
    treeJournal of Engineering Mechanics:;2019:;Volume ( 145 ):;issue: 004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian