    Experimental and Numerical Evaluation of Reinforced Concrete Walls Retrofit Systems for Blast Mitigation

    Source: Journal of Performance of Constructed Facilities:;2019:;Volume ( 033 ):;issue: 002
    Author:
    A. E. El-Sisi; A. Saucier; H. A. Salim; J. M. Hoemann
    DOI: 10.1061/(ASCE)CF.1943-5509.0001265
    Publisher: American Society of Civil Engineers
    Abstract: Various ductile sheet materials are currently being considered to retrofit existing concrete walls to mitigate the effects of external blast. In this paper, the blast mitigation of the soft and rigid sheet retrofit systems of reinforced concrete walls is studied. Different types of thin sheet retrofits, such as steel, rubber, polyurea, and polymer-fiber composite sheets, were examined by using a series of full-scale quasistatic tests to evaluate their static resistance. Finite-element modeling was performed to study the straining action of the wall elements, including the retrofit system. Nonlinear single-degree-of-freedom dynamic analysis was performed to calculate the blast response and study the mitigation effects of the various sheet materials considered. Experimental results showed that all retrofits exhibited significant energy absorption after a support rotation of 10°. Finite-element models were able to closely predict the static resistance function of these retrofitted walls. Parameters such as friction coefficient, end-connection gap due to slack in the sheet, and connection stiffness were investigated. It was found that by increasing the initial gap to account for slack, the membrane action is delayed, which increases the ductility of the wall and the area under the resistance-displacement curve. Increasing the friction and the stiffness of the end-connection increased the resistance and the overall energy absorption of the retrofitted wall system.
    • Download: (1.424Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Experimental and Numerical Evaluation of Reinforced Concrete Walls Retrofit Systems for Blast Mitigation

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4254611
    Collections
    • Journal of Performance of Constructed Facilities

    Show full item record

    contributor authorA. E. El-Sisi; A. Saucier; H. A. Salim; J. M. Hoemann
    date accessioned2019-03-10T11:59:49Z
    date available2019-03-10T11:59:49Z
    date issued2019
    identifier other%28ASCE%29CF.1943-5509.0001265.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4254611
    description abstractVarious ductile sheet materials are currently being considered to retrofit existing concrete walls to mitigate the effects of external blast. In this paper, the blast mitigation of the soft and rigid sheet retrofit systems of reinforced concrete walls is studied. Different types of thin sheet retrofits, such as steel, rubber, polyurea, and polymer-fiber composite sheets, were examined by using a series of full-scale quasistatic tests to evaluate their static resistance. Finite-element modeling was performed to study the straining action of the wall elements, including the retrofit system. Nonlinear single-degree-of-freedom dynamic analysis was performed to calculate the blast response and study the mitigation effects of the various sheet materials considered. Experimental results showed that all retrofits exhibited significant energy absorption after a support rotation of 10°. Finite-element models were able to closely predict the static resistance function of these retrofitted walls. Parameters such as friction coefficient, end-connection gap due to slack in the sheet, and connection stiffness were investigated. It was found that by increasing the initial gap to account for slack, the membrane action is delayed, which increases the ductility of the wall and the area under the resistance-displacement curve. Increasing the friction and the stiffness of the end-connection increased the resistance and the overall energy absorption of the retrofitted wall system.
    publisherAmerican Society of Civil Engineers
    titleExperimental and Numerical Evaluation of Reinforced Concrete Walls Retrofit Systems for Blast Mitigation
    typeJournal Paper
    journal volume33
    journal issue2
    journal titleJournal of Performance of Constructed Facilities
    identifier doi10.1061/(ASCE)CF.1943-5509.0001265
    page04018113
    treeJournal of Performance of Constructed Facilities:;2019:;Volume ( 033 ):;issue: 002
    contenttypeFulltext