Friction-Based Connectors for Timber Shear Walls: Static Experimental TestsSource: Journal of Architectural Engineering:;2019:;Volume ( 025 ):;issue: 002Author:Yoshiaki Wakashima; Hidemaru Shimizu; Koichiro Ishikawa; Yasushi Fujisawa; Solomon Tesfamariam
DOI: 10.1061/(ASCE)AE.1943-5568.0000351Publisher: American Society of Civil Engineers
Abstract: Timber shear wall systems dissipate energy through nail bending, nail withdrawal, and crushing of the sheathing around the nail hole. This dissipation mechanism is a pinching hysteretic response. Use of high-damping devices is an effective method for improving the earthquake resistance of a building. In this study, three wood friction connections were developed and tested to increase the damping of the wood shear walls. In this paper, cyclic experimental tests of the connectors and shear walls are presented. In addition, results of long-term performance assessments are also presented. The cyclic test response of the connections exhibited a rectangular hysteretic response, and the shear wall systems had an equivalent viscous damping ratio of around 0.3.
|
Collections
Show full item record
| contributor author | Yoshiaki Wakashima; Hidemaru Shimizu; Koichiro Ishikawa; Yasushi Fujisawa; Solomon Tesfamariam | |
| date accessioned | 2019-03-10T11:57:15Z | |
| date available | 2019-03-10T11:57:15Z | |
| date issued | 2019 | |
| identifier other | %28ASCE%29AE.1943-5568.0000351.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl1/handle/yetl/4254539 | |
| description abstract | Timber shear wall systems dissipate energy through nail bending, nail withdrawal, and crushing of the sheathing around the nail hole. This dissipation mechanism is a pinching hysteretic response. Use of high-damping devices is an effective method for improving the earthquake resistance of a building. In this study, three wood friction connections were developed and tested to increase the damping of the wood shear walls. In this paper, cyclic experimental tests of the connectors and shear walls are presented. In addition, results of long-term performance assessments are also presented. The cyclic test response of the connections exhibited a rectangular hysteretic response, and the shear wall systems had an equivalent viscous damping ratio of around 0.3. | |
| publisher | American Society of Civil Engineers | |
| title | Friction-Based Connectors for Timber Shear Walls: Static Experimental Tests | |
| type | Journal Paper | |
| journal volume | 25 | |
| journal issue | 2 | |
| journal title | Journal of Architectural Engineering | |
| identifier doi | 10.1061/(ASCE)AE.1943-5568.0000351 | |
| page | 04019006 | |
| tree | Journal of Architectural Engineering:;2019:;Volume ( 025 ):;issue: 002 | |
| contenttype | Fulltext |