    Comparative Analysis of Different Inlet Air Cooling Technologies Including Solar Energy to Boost Gas Turbine Combined Cycles in Hot Regions

    Source: Journal of Energy Resources Technology:;2018:;volume 140:;issue 011::page 112006
    Author:
    Abdel Rahman, Ahmed
    ,
    Mokheimer, Esmail M. A.
    DOI: 10.1115/1.4040195
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Cooling the air before entering the compressor of a gas turbine of combined cycle power plants is an effective method to boost the output power of the combined cycles in hot regions. This paper presents a comparative analysis for the effect of different air cooling technologies on increasing the output power of a combined cycle. It also presents a novel system of cooling the gas turbine inlet air using a solar-assisted absorption chiller. The effect of ambient air temperature and relative humidity on the output power is investigated and reported. The study revealed that at the design hour under the hot weather conditions, the total net power output of the plant drops from 268 MW to 226 MW at 48 °C (15.5% drop). The increase in the power output using fogging and evaporative cooling is less than that obtained with chillers since their ability to cool down the air is limited by the wet-bulb temperature. Integrating conventional and solar-assisted absorption chillers increased the net power output of the combined cycle by about 35 MW and 38 MW, respectively. Average and hourly performance during typical days have been conducted and presented. The plants without air inlet cooling system show higher carbon emissions (0.73 kg CO2/kWh) compared to the plant integrated with conventional and solar-assisted absorption chillers (0.509 kg CO2/kWh) and (0.508 kg CO2/kWh), respectively. Also, integrating a conventional absorption chiller shows the lowest capital cost and levelized electricity cost (LEC).
    • Download: (4.084Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Comparative Analysis of Different Inlet Air Cooling Technologies Including Solar Energy to Boost Gas Turbine Combined Cycles in Hot Regions

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4254190
    Collections
    • Journal of Energy Resources Technology

    Show full item record

    contributor authorAbdel Rahman, Ahmed
    contributor authorMokheimer, Esmail M. A.
    date accessioned2019-02-28T11:14:27Z
    date available2019-02-28T11:14:27Z
    date copyright6/12/2018 12:00:00 AM
    date issued2018
    identifier issn0195-0738
    identifier otherjert_140_11_112006.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4254190
    description abstractCooling the air before entering the compressor of a gas turbine of combined cycle power plants is an effective method to boost the output power of the combined cycles in hot regions. This paper presents a comparative analysis for the effect of different air cooling technologies on increasing the output power of a combined cycle. It also presents a novel system of cooling the gas turbine inlet air using a solar-assisted absorption chiller. The effect of ambient air temperature and relative humidity on the output power is investigated and reported. The study revealed that at the design hour under the hot weather conditions, the total net power output of the plant drops from 268 MW to 226 MW at 48 °C (15.5% drop). The increase in the power output using fogging and evaporative cooling is less than that obtained with chillers since their ability to cool down the air is limited by the wet-bulb temperature. Integrating conventional and solar-assisted absorption chillers increased the net power output of the combined cycle by about 35 MW and 38 MW, respectively. Average and hourly performance during typical days have been conducted and presented. The plants without air inlet cooling system show higher carbon emissions (0.73 kg CO2/kWh) compared to the plant integrated with conventional and solar-assisted absorption chillers (0.509 kg CO2/kWh) and (0.508 kg CO2/kWh), respectively. Also, integrating a conventional absorption chiller shows the lowest capital cost and levelized electricity cost (LEC).
    publisherThe American Society of Mechanical Engineers (ASME)
    titleComparative Analysis of Different Inlet Air Cooling Technologies Including Solar Energy to Boost Gas Turbine Combined Cycles in Hot Regions
    typeJournal Paper
    journal volume140
    journal issue11
    journal titleJournal of Energy Resources Technology
    identifier doi10.1115/1.4040195
    journal fristpage112006
    journal lastpage112006-13
    treeJournal of Energy Resources Technology:;2018:;volume 140:;issue 011
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian