    Assessment of Mechanical Characteristics of Ankle-Foot Orthoses

    Source: Journal of Biomechanical Engineering:;2018:;volume( 140 ):;issue: 007::page 71007
    Author:
    Wach, Amanda
    ,
    McGrady, Linda
    ,
    Wang, Mei
    ,
    Silver-Thorn, Barbara
    DOI: 10.1115/1.4039816
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Recent designs of ankle-foot orthoses (AFOs) have been influenced by the increasing demand for higher function from active individuals. The biomechanical function of the individual and device is dependent upon the underlying mechanical characteristics of the AFO. Prior mechanical testing of AFOs has primarily focused on rotational stiffness to provide insight into expected functional outcomes; mechanical characteristics pertaining to energy storage and release have not yet been investigated. A pseudostatic bench testing method is introduced to characterize compressive stiffness, device deflection, and motion of solid-ankle, anterior floor reaction, posterior leaf spring, and the intrepid dynamic exoskeletal orthosis (IDEO) AFOs. Each of these four AFOs, donned over a surrogate limb, were compressively loaded at different joint angles to simulate the foot-shank orientation during various subphases of stance. In addition to force–displacement measurements, deflection of each AFO strut and rotation of proximal and supramalleolar segments were analyzed. Although similar compressive stiffness values were observed for AFOs designed to reduce ankle motion, the corresponding strut deflection profile differed based on the respective fabrication material. For example, strut deflection of carbon-fiber AFOs resembled column buckling. Expanded clinical test protocols to include quantification of AFO deflection and rotation during subject use may provide additional insight into design and material effects on performance and functional outcomes, such as energy storage and release.
    • Download: (850.1Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Assessment of Mechanical Characteristics of Ankle-Foot Orthoses

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4253638
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorWach, Amanda
    contributor authorMcGrady, Linda
    contributor authorWang, Mei
    contributor authorSilver-Thorn, Barbara
    date accessioned2019-02-28T11:11:27Z
    date available2019-02-28T11:11:27Z
    date copyright4/30/2018 12:00:00 AM
    date issued2018
    identifier issn0148-0731
    identifier otherbio_140_07_071007.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4253638
    description abstractRecent designs of ankle-foot orthoses (AFOs) have been influenced by the increasing demand for higher function from active individuals. The biomechanical function of the individual and device is dependent upon the underlying mechanical characteristics of the AFO. Prior mechanical testing of AFOs has primarily focused on rotational stiffness to provide insight into expected functional outcomes; mechanical characteristics pertaining to energy storage and release have not yet been investigated. A pseudostatic bench testing method is introduced to characterize compressive stiffness, device deflection, and motion of solid-ankle, anterior floor reaction, posterior leaf spring, and the intrepid dynamic exoskeletal orthosis (IDEO) AFOs. Each of these four AFOs, donned over a surrogate limb, were compressively loaded at different joint angles to simulate the foot-shank orientation during various subphases of stance. In addition to force–displacement measurements, deflection of each AFO strut and rotation of proximal and supramalleolar segments were analyzed. Although similar compressive stiffness values were observed for AFOs designed to reduce ankle motion, the corresponding strut deflection profile differed based on the respective fabrication material. For example, strut deflection of carbon-fiber AFOs resembled column buckling. Expanded clinical test protocols to include quantification of AFO deflection and rotation during subject use may provide additional insight into design and material effects on performance and functional outcomes, such as energy storage and release.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleAssessment of Mechanical Characteristics of Ankle-Foot Orthoses
    typeJournal Paper
    journal volume140
    journal issue7
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.4039816
    journal fristpage71007
    journal lastpage071007-6
    treeJournal of Biomechanical Engineering:;2018:;volume( 140 ):;issue: 007
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian