    Development of a Computational Fluid Dynamics Model for Myocardial Bridging

    Source: Journal of Biomechanical Engineering:;2018:;volume( 140 ):;issue: 009::page 91010
    Author:
    Javadzadegan, Ashkan
    ,
    Moshfegh, Abouzar
    ,
    Fulker, David
    ,
    Barber, Tracie
    ,
    Qian, Yi
    ,
    Kritharides, Leonard
    ,
    Yong, Andy S. C.
    DOI: 10.1115/1.4040127
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Computational fluid dynamics (CFD) modeling of myocardial bridging (MB) remains challenging due to its dynamic and phasic nature. This study aims to develop a patient-specific CFD model of MB. There were two parts to this study. The first part consisted of developing an in silico model of the left anterior descending (LAD) coronary artery of a patient with MB. In this regard, a moving-boundary CFD algorithm was developed to simulate the patient-specific muscle compression caused by MB. A second simulation was also performed with the bridge artificially removed to determine the hemodynamics in the same vessel in the absence of MB. The second part of the study consisted of hemodynamic analysis of three patients with mild and moderate and severe MB in their LAD by means of the developed in silico model in the first part. The average shear stress in the proximal and bridge segments for model with MB were significantly different from those for model without MB (proximal segment: 0.32 ± 0.14 Pa (with MB) versus 0.97 ± 0.39 Pa (without MB), P < 0.0001 — bridge segment: 2.60 ± 0.94 Pa (with MB) versus 1.50 ± 0.64 Pa (without MB), P < 0.0001). When all three patients were evaluated, increasing the degree of vessel compression shear stress in the proximal segment decreased, whereas the shear stress in the bridge segment increased. The presence of MB resulted in hemodynamic abnormalities in the proximal segment, whereas segments within the bridge exhibited hemodynamic patterns which tend to discourage atheroma development.
    • Download: (5.866Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Development of a Computational Fluid Dynamics Model for Myocardial Bridging

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4253543
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorJavadzadegan, Ashkan
    contributor authorMoshfegh, Abouzar
    contributor authorFulker, David
    contributor authorBarber, Tracie
    contributor authorQian, Yi
    contributor authorKritharides, Leonard
    contributor authorYong, Andy S. C.
    date accessioned2019-02-28T11:10:54Z
    date available2019-02-28T11:10:54Z
    date copyright5/24/2018 12:00:00 AM
    date issued2018
    identifier issn0148-0731
    identifier otherbio_140_09_091010.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4253543
    description abstractComputational fluid dynamics (CFD) modeling of myocardial bridging (MB) remains challenging due to its dynamic and phasic nature. This study aims to develop a patient-specific CFD model of MB. There were two parts to this study. The first part consisted of developing an in silico model of the left anterior descending (LAD) coronary artery of a patient with MB. In this regard, a moving-boundary CFD algorithm was developed to simulate the patient-specific muscle compression caused by MB. A second simulation was also performed with the bridge artificially removed to determine the hemodynamics in the same vessel in the absence of MB. The second part of the study consisted of hemodynamic analysis of three patients with mild and moderate and severe MB in their LAD by means of the developed in silico model in the first part. The average shear stress in the proximal and bridge segments for model with MB were significantly different from those for model without MB (proximal segment: 0.32 ± 0.14 Pa (with MB) versus 0.97 ± 0.39 Pa (without MB), P < 0.0001 — bridge segment: 2.60 ± 0.94 Pa (with MB) versus 1.50 ± 0.64 Pa (without MB), P < 0.0001). When all three patients were evaluated, increasing the degree of vessel compression shear stress in the proximal segment decreased, whereas the shear stress in the bridge segment increased. The presence of MB resulted in hemodynamic abnormalities in the proximal segment, whereas segments within the bridge exhibited hemodynamic patterns which tend to discourage atheroma development.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleDevelopment of a Computational Fluid Dynamics Model for Myocardial Bridging
    typeJournal Paper
    journal volume140
    journal issue9
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.4040127
    journal fristpage91010
    journal lastpage091010-11
    treeJournal of Biomechanical Engineering:;2018:;volume( 140 ):;issue: 009
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian