    Integration of Soiling-Rate Measurements and Cleaning Strategies in Yield Analysis of Parabolic Trough Plants

    Source: Journal of Solar Energy Engineering:;2018:;volume( 140 ):;issue: 004::page 41008
    Author:
    Wolfertstetter, Fabian
    ,
    Wilbert, Stefan
    ,
    Dersch, Jürgen
    ,
    Dieckmann, Simon
    ,
    Pitz-Paal, Robert
    ,
    Ghennioui, Abdellatif
    DOI: 10.1115/1.4039631
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: The issue of reflector soiling becomes more important as concentrating solar thermal power plants (CSP) are being implemented at sites subject to high dust loads. In an operational power plant, a trade-off between reducing cleaning costs and cleaning related collector availability on the one hand and keeping the solar field cleanliness (ξfield) high to minimize soiling induced losses on the other hand must be found. The common yield analysis software packages system advisor model (SAM) and greenius only allow the input of a constant mean ξfield and constant cleaning costs. This oversimplifies real conditions because soiling is a highly time-dependent parameter and operators might adjust cleaning activities depending on factors such as soiling rate and irradiance. In this study, time-dependent soiling and cleaning data are used for modeling the yield of two parabolic trough plant configurations at two sites in Spain and Morocco. We apply a one-year soiling rate dataset in daily resolution measured with the tracking cleanliness sensor (TraCS). We use this as a basis to model the daily evolution of the cleanliness of each collector of a solar field resulting from the application of various cleaning strategies (CS). The thus obtained daily average ξfield is used to modify the inputs to the yield analysis software greenius. The cleaning costs for each CS are subtracted from the project's financial output parameters to accurately predict the yield of a CSP project over its lifetime. The profits obtained with different CSs are compared in a parameter variation analysis for two sites and the economically best CS is identified. The profit can be increased by more than 2.6% by the application of the best strategy relative to a reference strategy that uses a constant cleaning frequency. The error in profit calculated with constant soiling and cleaning parameters compared to the simulation with variable soiling and cleaning can be as high as 9.4%. With the presented method, temporally variable soiling rates and CS can be fully integrated to CSP yield analysis software, significantly increasing its accuracy. It can be used to determine optimum cleaning parameters.
    • Download: (2.948Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Integration of Soiling-Rate Measurements and Cleaning Strategies in Yield Analysis of Parabolic Trough Plants

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4252954
    Collections
    • Journal of Solar Energy Engineering

    Show full item record

    contributor authorWolfertstetter, Fabian
    contributor authorWilbert, Stefan
    contributor authorDersch, Jürgen
    contributor authorDieckmann, Simon
    contributor authorPitz-Paal, Robert
    contributor authorGhennioui, Abdellatif
    date accessioned2019-02-28T11:07:34Z
    date available2019-02-28T11:07:34Z
    date copyright4/9/2018 12:00:00 AM
    date issued2018
    identifier issn0199-6231
    identifier othersol_140_04_041008.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4252954
    description abstractThe issue of reflector soiling becomes more important as concentrating solar thermal power plants (CSP) are being implemented at sites subject to high dust loads. In an operational power plant, a trade-off between reducing cleaning costs and cleaning related collector availability on the one hand and keeping the solar field cleanliness (ξfield) high to minimize soiling induced losses on the other hand must be found. The common yield analysis software packages system advisor model (SAM) and greenius only allow the input of a constant mean ξfield and constant cleaning costs. This oversimplifies real conditions because soiling is a highly time-dependent parameter and operators might adjust cleaning activities depending on factors such as soiling rate and irradiance. In this study, time-dependent soiling and cleaning data are used for modeling the yield of two parabolic trough plant configurations at two sites in Spain and Morocco. We apply a one-year soiling rate dataset in daily resolution measured with the tracking cleanliness sensor (TraCS). We use this as a basis to model the daily evolution of the cleanliness of each collector of a solar field resulting from the application of various cleaning strategies (CS). The thus obtained daily average ξfield is used to modify the inputs to the yield analysis software greenius. The cleaning costs for each CS are subtracted from the project's financial output parameters to accurately predict the yield of a CSP project over its lifetime. The profits obtained with different CSs are compared in a parameter variation analysis for two sites and the economically best CS is identified. The profit can be increased by more than 2.6% by the application of the best strategy relative to a reference strategy that uses a constant cleaning frequency. The error in profit calculated with constant soiling and cleaning parameters compared to the simulation with variable soiling and cleaning can be as high as 9.4%. With the presented method, temporally variable soiling rates and CS can be fully integrated to CSP yield analysis software, significantly increasing its accuracy. It can be used to determine optimum cleaning parameters.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleIntegration of Soiling-Rate Measurements and Cleaning Strategies in Yield Analysis of Parabolic Trough Plants
    typeJournal Paper
    journal volume140
    journal issue4
    journal titleJournal of Solar Energy Engineering
    identifier doi10.1115/1.4039631
    journal fristpage41008
    journal lastpage041008-11
    treeJournal of Solar Energy Engineering:;2018:;volume( 140 ):;issue: 004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian