    Archive

    Design and Experimental Validation of an Active Catheter for Endovascular Navigation

    Source: Journal of Medical Devices:;2018:;volume( 012 ):;issue: 001::page 11003
    Author:
    Couture, Thibault
    ,
    Szewczyk, Jérôme
    DOI: 10.1115/1.4038334
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Endovascular techniques have many advantages but rely strongly on operator skills and experience. Robotically steerable catheters have been developed but few are clinically available. We describe here the development of an active and efficient catheter based on shape memory alloys (SMA) actuators. We first established the specifications of our device considering anatomical constraints. We then present a new method for building active SMA-based catheters. The proposed method relies on the use of a core body made of three parallel metallic beams and integrates wire-shaped SMA actuators. The complete device is encapsulated into a standard 6F catheter for safety purposes. A trial-and-error campaign comparing 70 different prototypes was conducted to determine the best dimensions of the core structure and of the SMA actuators with respect to the imposed specifications. The final prototype was tested on a silicon-based arterial model and on a 23 kg pig. During these experiments, we were able to cannulate the supra-aortic trunks and the renal arteries with different angulations and without any complication. A second major contribution of this paper is the derivation of a reliable mathematical model for predicting the bending angle of our active catheters. We first use this model to state some general qualitative rules useful for an iterative dimensional optimization. We then perform a quantitative comparison between the actual and the predicted bending angles for a set of 13 different prototypes. The relative error is less than 20% for bending angles between 100 deg and 150 deg, which is the interval of interest for our applications.
    • Download: (2.489Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Design and Experimental Validation of an Active Catheter for Endovascular Navigation

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4252442
    Collections
    • Journal of Medical Devices

    Show full item record

    contributor authorCouture, Thibault
    contributor authorSzewczyk, Jérôme
    date accessioned2019-02-28T11:04:45Z
    date available2019-02-28T11:04:45Z
    date copyright11/22/2017 12:00:00 AM
    date issued2018
    identifier issn1932-6181
    identifier othermed_012_01_011003.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4252442
    description abstractEndovascular techniques have many advantages but rely strongly on operator skills and experience. Robotically steerable catheters have been developed but few are clinically available. We describe here the development of an active and efficient catheter based on shape memory alloys (SMA) actuators. We first established the specifications of our device considering anatomical constraints. We then present a new method for building active SMA-based catheters. The proposed method relies on the use of a core body made of three parallel metallic beams and integrates wire-shaped SMA actuators. The complete device is encapsulated into a standard 6F catheter for safety purposes. A trial-and-error campaign comparing 70 different prototypes was conducted to determine the best dimensions of the core structure and of the SMA actuators with respect to the imposed specifications. The final prototype was tested on a silicon-based arterial model and on a 23 kg pig. During these experiments, we were able to cannulate the supra-aortic trunks and the renal arteries with different angulations and without any complication. A second major contribution of this paper is the derivation of a reliable mathematical model for predicting the bending angle of our active catheters. We first use this model to state some general qualitative rules useful for an iterative dimensional optimization. We then perform a quantitative comparison between the actual and the predicted bending angles for a set of 13 different prototypes. The relative error is less than 20% for bending angles between 100 deg and 150 deg, which is the interval of interest for our applications.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleDesign and Experimental Validation of an Active Catheter for Endovascular Navigation
    typeJournal Paper
    journal volume12
    journal issue1
    journal titleJournal of Medical Devices
    identifier doi10.1115/1.4038334
    journal fristpage11003
    journal lastpage011003-12
    treeJournal of Medical Devices:;2018:;volume( 012 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian