Experimental Study About Performance Analysis of Parallel Connected Ranque–Hilsch Counter Flow Vortex Tubes With Different Nozzle Numbers and MaterialsSource: Journal of Heat Transfer:;2018:;volume( 140 ):;issue: 011::page 112801DOI: 10.1115/1.4040707Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: An experimental analysis for parallel connected two identical counter flow Ranque–Hilsch vortex tubes (RHVT) with different nozzle materials and numbers was conducted by using compressed air as a working fluid in this paper. Heating and cooling performance of vortex tube system (circuit) and the results of exergy analysis are researched comprehensively according to different inlet pressure, nozzle numbers, and materials. Nozzles made of polyamide plastic, aluminum, and brass were mounted into the vortex tubes individually for each case of experimental investigation with the numbers of nozzles 2, 3, 4, 5, and 6. The range of operated inlet pressure 150–550 kPa with 50 kPa variation. The ratio of length–diameter (L/D) of each vortex tube in the circuit is 14 and the cold mass fraction is 0.36. Coefficient of performance (COP) values, heating, and cooling capacity of the parallel connected RHVT system were evaluated. Further, an exergy analysis was carried out to evaluate the energy losses and second law efficiency of the vortex tube circuit. The greatest thermal performance was obtained with aluminum-six-nozzle when taking into account all parameters such as temperature difference, COP values, heating and cooling capacity, and exergy analysis.
|
Collections
Show full item record
| contributor author | Kaya, Hüseyin | |
| contributor author | Günver, Fahrettin | |
| contributor author | Uluer, Onuralp | |
| contributor author | Kırmacı, Volkan | |
| date accessioned | 2019-02-28T11:00:59Z | |
| date available | 2019-02-28T11:00:59Z | |
| date copyright | 7/23/2018 12:00:00 AM | |
| date issued | 2018 | |
| identifier issn | 0022-1481 | |
| identifier other | ht_140_11_112801.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl1/handle/yetl/4251751 | |
| description abstract | An experimental analysis for parallel connected two identical counter flow Ranque–Hilsch vortex tubes (RHVT) with different nozzle materials and numbers was conducted by using compressed air as a working fluid in this paper. Heating and cooling performance of vortex tube system (circuit) and the results of exergy analysis are researched comprehensively according to different inlet pressure, nozzle numbers, and materials. Nozzles made of polyamide plastic, aluminum, and brass were mounted into the vortex tubes individually for each case of experimental investigation with the numbers of nozzles 2, 3, 4, 5, and 6. The range of operated inlet pressure 150–550 kPa with 50 kPa variation. The ratio of length–diameter (L/D) of each vortex tube in the circuit is 14 and the cold mass fraction is 0.36. Coefficient of performance (COP) values, heating, and cooling capacity of the parallel connected RHVT system were evaluated. Further, an exergy analysis was carried out to evaluate the energy losses and second law efficiency of the vortex tube circuit. The greatest thermal performance was obtained with aluminum-six-nozzle when taking into account all parameters such as temperature difference, COP values, heating and cooling capacity, and exergy analysis. | |
| publisher | The American Society of Mechanical Engineers (ASME) | |
| title | Experimental Study About Performance Analysis of Parallel Connected Ranque–Hilsch Counter Flow Vortex Tubes With Different Nozzle Numbers and Materials | |
| type | Journal Paper | |
| journal volume | 140 | |
| journal issue | 11 | |
| journal title | Journal of Heat Transfer | |
| identifier doi | 10.1115/1.4040707 | |
| journal fristpage | 112801 | |
| journal lastpage | 112801-8 | |
| tree | Journal of Heat Transfer:;2018:;volume( 140 ):;issue: 011 | |
| contenttype | Fulltext |