    A Study of Supercritical Carbon Dioxide Power Cycle for Concentrating Solar Power Applications Using an Isothermal Compressor

    Source: Journal of Engineering for Gas Turbines and Power:;2018:;volume( 140 ):;issue: 007::page 71702
    Author:
    Young Heo, Jin
    ,
    Kwon, Jinsu
    ,
    Ik Lee, Jeong
    DOI: 10.1115/1.4038476
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: For the concentrating solar power (CSP) applications, the supercritical carbon dioxide (s-CO2) power cycle is beneficial in many aspects, including high cycle efficiencies, reduced component sizing, and potential for the dry cooling option. More research is involved in improving this technology to realize the s-CO2 cycle as a candidate to replace the conventional power conversion systems for CSP applications. In this study, an isothermal compressor, a turbomachine which undergoes the compression process at constant temperature to minimize compression work, is applied to the s-CO2 power cycle layout. To investigate the cycle performance changes of adopting the novel technology, a framework for defining the efficiency of the isothermal compressor is revised and suggested. This study demonstrates how the compression work for the isothermal compressor is reduced, up to 50%, compared to that of the conventional compressor under varying compressor inlet conditions. Furthermore, the simple recuperated and recompression Brayton cycle layouts using s-CO2 as a working fluid are evaluated for the CSP applications. Results show that for compressor inlet temperatures (CIT) near the critical point, the recompression Brayton cycle using an isothermal compressor has 0.2–1.0% point higher cycle thermal efficiency compared to its reference cycle. For higher CIT values, the recompression cycle using an isothermal compressor can perform above 50% in thermal efficiency for a wider range of CIT than the reference cycle. Adopting an isothermal compressor in the s-CO2 layout can imply larger heat exchange area for the compressor which requires further development.
    • Download: (1.166Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      A Study of Supercritical Carbon Dioxide Power Cycle for Concentrating Solar Power Applications Using an Isothermal Compressor

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4251371
    Collections
    • Journal of Engineering for Gas Turbines and Power

    Show full item record

    contributor authorYoung Heo, Jin
    contributor authorKwon, Jinsu
    contributor authorIk Lee, Jeong
    date accessioned2019-02-28T10:58:46Z
    date available2019-02-28T10:58:46Z
    date copyright4/10/2018 12:00:00 AM
    date issued2018
    identifier issn0742-4795
    identifier othergtp_140_07_071702.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4251371
    description abstractFor the concentrating solar power (CSP) applications, the supercritical carbon dioxide (s-CO2) power cycle is beneficial in many aspects, including high cycle efficiencies, reduced component sizing, and potential for the dry cooling option. More research is involved in improving this technology to realize the s-CO2 cycle as a candidate to replace the conventional power conversion systems for CSP applications. In this study, an isothermal compressor, a turbomachine which undergoes the compression process at constant temperature to minimize compression work, is applied to the s-CO2 power cycle layout. To investigate the cycle performance changes of adopting the novel technology, a framework for defining the efficiency of the isothermal compressor is revised and suggested. This study demonstrates how the compression work for the isothermal compressor is reduced, up to 50%, compared to that of the conventional compressor under varying compressor inlet conditions. Furthermore, the simple recuperated and recompression Brayton cycle layouts using s-CO2 as a working fluid are evaluated for the CSP applications. Results show that for compressor inlet temperatures (CIT) near the critical point, the recompression Brayton cycle using an isothermal compressor has 0.2–1.0% point higher cycle thermal efficiency compared to its reference cycle. For higher CIT values, the recompression cycle using an isothermal compressor can perform above 50% in thermal efficiency for a wider range of CIT than the reference cycle. Adopting an isothermal compressor in the s-CO2 layout can imply larger heat exchange area for the compressor which requires further development.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleA Study of Supercritical Carbon Dioxide Power Cycle for Concentrating Solar Power Applications Using an Isothermal Compressor
    typeJournal Paper
    journal volume140
    journal issue7
    journal titleJournal of Engineering for Gas Turbines and Power
    identifier doi10.1115/1.4038476
    journal fristpage71702
    journal lastpage071702-8
    treeJournal of Engineering for Gas Turbines and Power:;2018:;volume( 140 ):;issue: 007
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian