YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • Journal of Engineering for Gas Turbines and Power
    • View Item
    •   YE&T Library
    • ASME
    • Journal of Engineering for Gas Turbines and Power
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Performance Evaluation of a Molten Carbonate Fuel Cell/Micro Gas Turbine Hybrid System With Oxy-Combustion Carbon Capture

    Source: Journal of Engineering for Gas Turbines and Power:;2018:;volume( 140 ):;issue: 004::page 41502
    Author:
    Ahn, Ji Ho
    ,
    Seop Kim, Tong
    DOI: 10.1115/1.4038038
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Owing to the increasing consumption of fossil fuels and emission of greenhouse gases, interests in highly efficient and low carbon emitting power systems are growing fast. Several research groups have been suggesting advanced systems based on fuel cells and have also been applying carbon capture and storage technology to satisfy the demand for clean energy. In this study, the performance of a hybrid system, which is a combination of a molten carbonate fuel cell (MCFC) with oxy-combustion carbon capture and an indirectly fired micro gas turbine (MGT), was predicted. A 2.5 MW MCFC system that is used in commercial applications was used as the reference system so that the results of the study could be applied to practical situations. The ambient pressure type hybrid system was modeled by referring to the design parameters of an MGT that is currently being developed. A semi-closed type design characterized by flow recirculation was adopted for this hybrid system. A part of the recirculating gas is converted into liquefied carbon dioxide and captured for storage at the carbon separation unit (CSU). Almost 100% carbon dioxide capture is possible with this system. In these systems, the output power of the fuel cell is larger than in the normal hybrid system without carbon capture because the partial pressure of carbon dioxide increases. The increased cell power partially compensates for the power loss due to the carbon capture and MGT power reduction. The dependence of net system efficiency of the oxy-hybrid on compressor pressure ratio is marginal, especially beyond an optimal value.
    • Download: (729.3Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Performance Evaluation of a Molten Carbonate Fuel Cell/Micro Gas Turbine Hybrid System With Oxy-Combustion Carbon Capture

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4251041
    Collections
    • Journal of Engineering for Gas Turbines and Power

    Show full item record

    contributor authorAhn, Ji Ho
    contributor authorSeop Kim, Tong
    date accessioned2019-02-28T10:56:42Z
    date available2019-02-28T10:56:42Z
    date copyright10/31/2017 12:00:00 AM
    date issued2018
    identifier issn0742-4795
    identifier othergtp_140_04_041502.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4251041
    description abstractOwing to the increasing consumption of fossil fuels and emission of greenhouse gases, interests in highly efficient and low carbon emitting power systems are growing fast. Several research groups have been suggesting advanced systems based on fuel cells and have also been applying carbon capture and storage technology to satisfy the demand for clean energy. In this study, the performance of a hybrid system, which is a combination of a molten carbonate fuel cell (MCFC) with oxy-combustion carbon capture and an indirectly fired micro gas turbine (MGT), was predicted. A 2.5 MW MCFC system that is used in commercial applications was used as the reference system so that the results of the study could be applied to practical situations. The ambient pressure type hybrid system was modeled by referring to the design parameters of an MGT that is currently being developed. A semi-closed type design characterized by flow recirculation was adopted for this hybrid system. A part of the recirculating gas is converted into liquefied carbon dioxide and captured for storage at the carbon separation unit (CSU). Almost 100% carbon dioxide capture is possible with this system. In these systems, the output power of the fuel cell is larger than in the normal hybrid system without carbon capture because the partial pressure of carbon dioxide increases. The increased cell power partially compensates for the power loss due to the carbon capture and MGT power reduction. The dependence of net system efficiency of the oxy-hybrid on compressor pressure ratio is marginal, especially beyond an optimal value.
    publisherThe American Society of Mechanical Engineers (ASME)
    titlePerformance Evaluation of a Molten Carbonate Fuel Cell/Micro Gas Turbine Hybrid System With Oxy-Combustion Carbon Capture
    typeJournal Paper
    journal volume140
    journal issue4
    journal titleJournal of Engineering for Gas Turbines and Power
    identifier doi10.1115/1.4038038
    journal fristpage41502
    journal lastpage041502-11
    treeJournal of Engineering for Gas Turbines and Power:;2018:;volume( 140 ):;issue: 004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian