YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASCE
    • Journal of Bridge Engineering
    • View Item
    •   YE&T Library
    • ASCE
    • Journal of Bridge Engineering
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    HyFRC Bridge Piers with Different Detailing at Pier–Foundation Interface

    Source: Journal of Bridge Engineering:;2018:;Volume ( 023 ):;issue: 006
    Author:
    Kotoky Needhi;Deb Sajal K.;Dutta Anjan
    DOI: 10.1061/(ASCE)BE.1943-5592.0001243
    Publisher: American Society of Civil Engineers
    Abstract: This article presents the results of an experimental investigation to evaluate the effectiveness of the use of hybrid fiber-reinforced concrete (HyFRC) along with some additional detailing features at the pier–foundation interface for improved seismic performance. Two different fibers, namely, steel and polypropylene, of appropriate volume fraction were mixed with concrete to obtain HyFRC. Three different detailing strategies were considered at the region of the pier–foundation interface. Whereas normal reinforcement details were followed for Specimen 1, additional reinforcing bars (dowels) were used in the interface region for Specimen 2, and corrugated sheet duct was used below the interface region in Specimen 3. In this study, detailed strain measurements at predefined locations were correlated with the enhancement of displacement ductility and energy dissipation in different test specimens. Hybrid simulation was used with input excitations of different intensity levels to evaluate the seismic performance of HyFRC bridge piers. The simulation was conducted in a manner such that the specimens experienced different levels of damage. Further, after the completion of the hybrid test, cyclic tests were conducted to evaluate the ultimate capacities of these specimens. The piers with dowel reinforcement at the interface region were found to be better than the other two types for the considered seismic performance parameters, such as delayed growth of strain, improved damage tolerance, enhanced energy-dissipation capacity, higher stiffness at any drift ratio, and improved load-carrying capacity. Further, specimens with HyFRC outperformed all the corresponding specimens made of conventional concrete in terms of all of the aforementioned parameters characterizing enhanced seismic performance.
    • Download: (3.170Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      HyFRC Bridge Piers with Different Detailing at Pier–Foundation Interface

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4250319
    Collections
    • Journal of Bridge Engineering

    Show full item record

    contributor authorKotoky Needhi;Deb Sajal K.;Dutta Anjan
    date accessioned2019-02-26T07:55:35Z
    date available2019-02-26T07:55:35Z
    date issued2018
    identifier other%28ASCE%29BE.1943-5592.0001243.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4250319
    description abstractThis article presents the results of an experimental investigation to evaluate the effectiveness of the use of hybrid fiber-reinforced concrete (HyFRC) along with some additional detailing features at the pier–foundation interface for improved seismic performance. Two different fibers, namely, steel and polypropylene, of appropriate volume fraction were mixed with concrete to obtain HyFRC. Three different detailing strategies were considered at the region of the pier–foundation interface. Whereas normal reinforcement details were followed for Specimen 1, additional reinforcing bars (dowels) were used in the interface region for Specimen 2, and corrugated sheet duct was used below the interface region in Specimen 3. In this study, detailed strain measurements at predefined locations were correlated with the enhancement of displacement ductility and energy dissipation in different test specimens. Hybrid simulation was used with input excitations of different intensity levels to evaluate the seismic performance of HyFRC bridge piers. The simulation was conducted in a manner such that the specimens experienced different levels of damage. Further, after the completion of the hybrid test, cyclic tests were conducted to evaluate the ultimate capacities of these specimens. The piers with dowel reinforcement at the interface region were found to be better than the other two types for the considered seismic performance parameters, such as delayed growth of strain, improved damage tolerance, enhanced energy-dissipation capacity, higher stiffness at any drift ratio, and improved load-carrying capacity. Further, specimens with HyFRC outperformed all the corresponding specimens made of conventional concrete in terms of all of the aforementioned parameters characterizing enhanced seismic performance.
    publisherAmerican Society of Civil Engineers
    titleHyFRC Bridge Piers with Different Detailing at Pier–Foundation Interface
    typeJournal Paper
    journal volume23
    journal issue6
    journal titleJournal of Bridge Engineering
    identifier doi10.1061/(ASCE)BE.1943-5592.0001243
    page4018035
    treeJournal of Bridge Engineering:;2018:;Volume ( 023 ):;issue: 006
    contenttypeFulltext