YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASCE
    • Journal of Bridge Engineering
    • View Item
    •   YE&T Library
    • ASCE
    • Journal of Bridge Engineering
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Lap-Spliced Rebar Connections with UHPC Closures

    Source: Journal of Bridge Engineering:;2018:;Volume ( 023 ):;issue: 006
    Author:
    Haber Zachary B.;Graybeal Benjamin A.
    DOI: 10.1061/(ASCE)BE.1943-5592.0001239
    Publisher: American Society of Civil Engineers
    Abstract: Ultrahigh performance concrete (UHPC) is gaining attention from the bridge community as a compelling option for closure pours that complete prefabricated bridge element (PBE) connections; these connections typically use field-cast UHPC cast over noncontact lap-spliced reinforcing bars to achieve structural continuity between elements. The goal of this study was to investigate the behavior of different commercially available UHPC-class materials for prefabricated bridge deck connections using noncontact lap splices. Two types of experiments were conducted to assess performance: a direct tension pullout test and a component-level prefabricated-bridge-deck connection test. The objective of the pullout testing was to investigate the effect of the UHPC fiber-volume fraction on UHPC-to-rebar bond strength and compare the performances of different UHPC specimens with existing design guidance. Component-level testing was used to investigate the bond between the UHPC and precast concrete, cracking behavior under cyclic loading, behavior during long-term cyclic loading, and monotonic ultimate-loading behavior. Findings indicated that available design guidance held for different UHPC-class materials. Furthermore, test results were used to propose additional guidance related to the UHPC fiber-volume fraction and cover requirements.
    • Download: (3.421Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Lap-Spliced Rebar Connections with UHPC Closures

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4250296
    Collections
    • Journal of Bridge Engineering

    Show full item record

    contributor authorHaber Zachary B.;Graybeal Benjamin A.
    date accessioned2019-02-26T07:55:20Z
    date available2019-02-26T07:55:20Z
    date issued2018
    identifier other%28ASCE%29BE.1943-5592.0001239.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4250296
    description abstractUltrahigh performance concrete (UHPC) is gaining attention from the bridge community as a compelling option for closure pours that complete prefabricated bridge element (PBE) connections; these connections typically use field-cast UHPC cast over noncontact lap-spliced reinforcing bars to achieve structural continuity between elements. The goal of this study was to investigate the behavior of different commercially available UHPC-class materials for prefabricated bridge deck connections using noncontact lap splices. Two types of experiments were conducted to assess performance: a direct tension pullout test and a component-level prefabricated-bridge-deck connection test. The objective of the pullout testing was to investigate the effect of the UHPC fiber-volume fraction on UHPC-to-rebar bond strength and compare the performances of different UHPC specimens with existing design guidance. Component-level testing was used to investigate the bond between the UHPC and precast concrete, cracking behavior under cyclic loading, behavior during long-term cyclic loading, and monotonic ultimate-loading behavior. Findings indicated that available design guidance held for different UHPC-class materials. Furthermore, test results were used to propose additional guidance related to the UHPC fiber-volume fraction and cover requirements.
    publisherAmerican Society of Civil Engineers
    titleLap-Spliced Rebar Connections with UHPC Closures
    typeJournal Paper
    journal volume23
    journal issue6
    journal titleJournal of Bridge Engineering
    identifier doi10.1061/(ASCE)BE.1943-5592.0001239
    page4018028
    treeJournal of Bridge Engineering:;2018:;Volume ( 023 ):;issue: 006
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian