    Performance Evaluation of Profile Probe for Continuous Monitoring of Volumetric Water Content in Multilayered Cover System

    Source: Journal of Environmental Engineering:;2018:;Volume ( 144 ):;issue: 009
    Author:
    Shaikh Janarul;Yamsani Sudheer Kumar;Sekharan Sreedeep;Rakesh Ravi R.
    DOI: 10.1061/(ASCE)EE.1943-7870.0001424
    Publisher: American Society of Civil Engineers
    Abstract: A profile probe (PP) is a handy instrument for simultaneously measuring volumetric water content (θ) at shallow multiple depths in the field. The accuracy of the θ measurement is important for moisture migration and water balance studies associated with the multilayered cover system (MLCS) provided over nonoperational landfills. There are no guidelines or controlled procedure for evaluating the accuracy of a PP for varying layers of an MLCS. A simple laboratory setup is developed in this study to evaluate all six sensors of a PP simultaneously for a particular soil type and compaction state. The results obtained from this study were used to improve the accuracy of PP measurements for the type of soils generally used in MLCSs. The validity of the proposed procedure was further evaluated based on a new set of PP measurements. The procedure adopted in this study improved the accuracy of PP measurement from ±6% to ±1%. The most interesting observation is the parity in sensor readings by following the proposed procedure, which was initially found to be different. The results from this study indicated that improper θ measurements can result in an error as high as 18% in the determination of change in soil water storage for different layers of a trial MLCS. Adopting the procedure proposed in this study ensures reliable and precise θ measurements for the materials used in MLCS for all the sensors of PP. In the absence of soil-specific calibration for PP, the equations proposed in this study can be used for the type of soils used in MLCSs.
    • Download: (1.942Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Performance Evaluation of Profile Probe for Continuous Monitoring of Volumetric Water Content in Multilayered Cover System

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4248703
    Collections
    • Journal of Environmental Engineering

    Show full item record

    contributor authorShaikh Janarul;Yamsani Sudheer Kumar;Sekharan Sreedeep;Rakesh Ravi R.
    date accessioned2019-02-26T07:41:00Z
    date available2019-02-26T07:41:00Z
    date issued2018
    identifier other%28ASCE%29EE.1943-7870.0001424.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4248703
    description abstractA profile probe (PP) is a handy instrument for simultaneously measuring volumetric water content (θ) at shallow multiple depths in the field. The accuracy of the θ measurement is important for moisture migration and water balance studies associated with the multilayered cover system (MLCS) provided over nonoperational landfills. There are no guidelines or controlled procedure for evaluating the accuracy of a PP for varying layers of an MLCS. A simple laboratory setup is developed in this study to evaluate all six sensors of a PP simultaneously for a particular soil type and compaction state. The results obtained from this study were used to improve the accuracy of PP measurements for the type of soils generally used in MLCSs. The validity of the proposed procedure was further evaluated based on a new set of PP measurements. The procedure adopted in this study improved the accuracy of PP measurement from ±6% to ±1%. The most interesting observation is the parity in sensor readings by following the proposed procedure, which was initially found to be different. The results from this study indicated that improper θ measurements can result in an error as high as 18% in the determination of change in soil water storage for different layers of a trial MLCS. Adopting the procedure proposed in this study ensures reliable and precise θ measurements for the materials used in MLCS for all the sensors of PP. In the absence of soil-specific calibration for PP, the equations proposed in this study can be used for the type of soils used in MLCSs.
    publisherAmerican Society of Civil Engineers
    titlePerformance Evaluation of Profile Probe for Continuous Monitoring of Volumetric Water Content in Multilayered Cover System
    typeJournal Paper
    journal volume144
    journal issue9
    journal titleJournal of Environmental Engineering
    identifier doi10.1061/(ASCE)EE.1943-7870.0001424
    page4018078
    treeJournal of Environmental Engineering:;2018:;Volume ( 144 ):;issue: 009
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian